Laserfiche WebLink
FORM f�405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method ' <br /> Project Name. 1450 sf ADS Builder Name: Lennar Homes '� <br /> street: 36095 Carriage Pine Court Permit office: City of�phyz'hills <br /> City,State,Zip� , FL, Permit Number:��� <br /> Owner• Lennar Homes Jurisdiction: (j (00 � <br /> Design Location: FL,Tampa <br /> 1 New construction or existing New(From Plans) 9. Wall Types(1394.7 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1136.00 ftZ <br /> b. Frame-Wood,Adjacent R=11.0 258.67 ft2 <br /> 3. Number of units, if multiple family 1 c.N/A R= ftz <br /> 4. Number of Bedrooms 3 d. N/A R= ftz <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1461.0 sqft.) Insulation Area Z <br /> a. Under Attic(Vented) R=30.0 839.00 ft <br /> 6. Conditioned floor area above grade(ftZ) 1461 b.Cathedral/Single Assembly(Vented) R=30.0 622.00 ftz <br /> Conditioned floor area below grade(ftz) 0 c. N/A R= ftZ <br /> 11.Ducts R ftz <br /> 7 Windows(111.0 sqft.) Description Area a.Sup�Attic,Ret:Main,AH:Main 6 292.2 <br /> a. U-Factor: Dbl, U=0.54 71.00 ftz <br /> SHGC• SHGC=0.31 <br /> b U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC• ' SHGC=0.32 a.Central Unit 25.2 SEER.16.20 <br /> c. U-Factor: Dbl,U=0.56 6.68 ftz <br /> SHGC� SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A ft2 a.Electric Heat Pump 21.8 HSPF:9.00 <br /> SHGC� <br /> Area Weighted Average Overhang Depth: 1.601 ft. <br />, Area Weighted Average SHGC• 0.311 14.Hot water systems <br /> a. Electric Cap:40 gallons <br /> 8. Floor Types (1461.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1461.00 ftz b. Conservation features <br /> b.N/A R= ft2 None <br /> c. N/A � R= ft2 15.Credits Pstat <br /> Glass/FloorArea. 0.076 Total Proposed Modified Loads 46.20 pASS <br /> Total Baseline Loads: 46.32 <br /> I hereby certify that the plans and specifications covered by Review of the plans and Q����:�T.q�,�, �. <br /> this calculation are in compliance with the Florida Energy specifications covered by this y ; , _ .�� O�, <br /> Code. calculation indicates compliance �'��:n,°'' ':��;.�' <br /> wit h t he F lori da Energy Co de. �+ jurri�%�; :r±,'�"�';.*���,���C> <br /> �a ve �G�l�rcl� r.::.:.._ <br /> P R E P A R E D B Y: B e f o r e c o n s t r u c t i o n i s c o m p l e t e d t i ;-.� � � <br /> DATE. this building will be inspected for c,�,� ;"1'�,�,`�'i � ,� _ <br /> compliance with Section 553.908 * � �' •. � <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. � � �,�*�:. <br /> with the Florida Energy Code. �U'�rv�'� <br /> OWNER/AGENT: BUILDING O I I : <br /> DATE: � DATE: - '� <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as / <br />� certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 12/30/2016 10:30 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Sofiware Page 1 of 4 I <br />