Laserfiche WebLink
lZ lZ W Building Consultants, Inc. <br /> WConsulting and Engineering Services for the Building Industry <br /> B P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 <br /> CFlorida Board of ProCcssional Engineers Certificate of Auti�orization No.9813 <br /> . � � ��� � <br /> � / / '// <br /> � / <br /> Product Sub Category Manufacturer Product Name <br /> Category <br /> Associated Materials Inc. 3004/3B04 I 3A04/03A4/0354 <br /> Window Fixed 3773 State Road Vinly Fixed."ReplacemenY'Window <br /> Cuyahoga Falls,ON 44223 "Non-Impact" <br /> Phone 330.922.2108 <br /> Scope: Product Evaluation report issued by R W Building Consultants,Inc.&Lyndon F.Schmidt,P.E.(System ID#1998)for <br /> Associated Materials Inc.,based on Rule Chapter No.61 G20-3, Method 1 D of the State of Florida Product Approval,Dept. <br /> of Business&Professional Regulation. <br /> RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company <br /> manufacturing or distributing the product or in any other entity involved in the approval process of the product named <br /> hereiri. <br /> Limitations: <br /> 1. This product has been evaluated and is in compliance with the 5th Edifion(2014)Florida Building Code structural requirements <br /> excluding the"High Velocity Hurricane Zone". <br /> 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing <br /> or stucco. <br /> 3. When used in areas requiring wind bome debris protecfion,this product is required to be protected with an impact resistant covering <br /> that complies with Section 1609.1.2 of the Florida Building Code. <br /> 4. For 2x stud framing construction,anchoring of these units shatl be the same as that shown for 2x buck masonry construction_ <br /> 5. Site conditions that deviate from the details of drawing FL-990923 require further engineering analysis by a licensed engineer or <br /> registered architect. <br /> 6. See drawing FL-9909.23 for size and design pressure limitations. <br /> Supporting Documents: � <br /> 1. Test Reaort No. Test Standard Testinq Laboratorv Siqned bv <br /> ATI D0849.01-501-47 AAMA/WDMA/CSA101/1.S.2/A440-08 Archifectural Testing Inc. Lynn George <br /> 2. Drawina No. Prepared bv Signed&Sealed bv <br /> No.FL-9909.23 F2W Building Consultants,Inc. (CA#9813) . Lyndon F.Schmidt,P.E. <br /> 3. Calculations Prepared bv Siqned�Sealed bv <br /> ProductAnchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> 4. QualitvAssurance eaa�teeaaoeli�oos <br /> Certificate of Participation issued by Architectural Testing, Inc., �,�ae F,SCHi4j��eso� <br /> certifying that Associated Materials lnc.is manufacturing products �e �.-,.-G�jy••• A o� <br /> within a quality assurance program that complies with ISO/IEC 0oe :��,� S�-•�. eoa <br /> 17020 and Guide 53 v� o �o qgqpg �:�c <br /> — : w r <br /> ��� ' � <br /> s <br /> O'� Si'ATE OF ���U 4 <br /> ��B��'�,< p R�O p-'\ eoe <br /> e,�s�sos°Oa►,lse a�a�°�A,o <br /> i Lyndon F.Schmidt,P.E. <br /> FL PE No.43409 <br /> Sheet 1 of 1 8/18/2016 <br />� <br />