TRINITY I E�D �
<br /> TABLE 1A:.WOOD DECKS—NEW CONSTRUCTION oR REROOF(TenR-OFF)
<br /> SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED lNSULATION,BONDED ROOF COVER' •
<br /> Sys. Deck Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 14) MDP
<br /> No. (Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Cap (psf)
<br /> Min.19/32- 32 ga.,1-5/8- 8-inch o.c.in 3-inch Min.1.5-inch
<br /> inch Glasbase;Flintglas inch dia.tin lap and 8-inch o.c. ACFoam II, (Optional) SBS-AA,
<br /> BP-AA,SBS- SBS-TA
<br /> W-7 plywood at Premium Ply Sheet caps with 11 ga. in three(3),equally FlintBoard ISO, HA None N/A SBS-SA-H � SBS-TA or APP- -60.0
<br /> max.24- Type VI;Yosemite annular ring spaced,staggered ENRGY-3,H-Shield
<br /> or APP-TA TA
<br /> inch shank nails center rows or Multi-Max FA3
<br /> CONVENTIONALSYSTEMS:
<br /> Glasbase,All
<br /> Min.19/32- 32 ga.,1-5/8- 9-inch o.c.in 4-inch Min.1.5-inch Min.0.25-inch gp_qA, (Optional) SBS-AA,
<br /> Weather Empire,
<br /> inch inch dia.tin lap and 12-inch o.c. ACFoam II, Dens Deck SBS-AA, BP-AA,SBS- SBS-TA
<br /> W-8 plywood at Flexiglas Base, caps with 11 ga. in two(2),equally FlintBoard I50, HA primed with HA -45.0*
<br /> Flintlastic Base 20; SBS-TA or AA,SBS-TA or APP-
<br /> max.24- annular ring spaced,staggered ENRGY-3,H-Shield FlintPrime(ASTM
<br /> inch spans Poly SMS;Ultra Poly shank nails center rows or Multi-Max FA3 D41)primer APP-TA or APP-TA TA
<br /> SMS•Yosemite
<br /> HA full HA full
<br /> Min.19/32- Glasbase,All 32 ga.,1-5/8- 8-inch o.c.in 3-inch Min.1.5-inch coverege or Min.0.25-inch coverage or BP-AA, (Optional) SBS-AA,
<br /> inch Weather Empire, inch dia.tin lap and 8-inch o.c. ACFoam II, Dens Deck
<br /> OB500,M- OB500,M- SBS-AA, BP-AA,SBS- 5B5-TA
<br /> W-9 plywood at Flexiglas Base,Poly caps with 11 ga. in three(3),equally FlintBoard ISO, primed with -52.5
<br /> OSFA,A-PD, OSFA,A-PD,D- SBS-TA or AA,SBS-TA or APP-
<br /> max.24- SMS or Ultra Poly annular ring spaced,staggered ENRGY-3,H-Shield D-IS or CR-20, FlintPrime(ASTM IS or CR-20,6- APP-TA or APP-TA TA
<br /> inch spans SMS shank nails center rows or Multi-Max FA3 4-inch o.c. D41)primer inch o.c.
<br /> Min.19/32- 32 ga.,1-5/8- 8-inch o.c.in 3-inch Min.1.5-inch Min.0.25-inch gp_AA, (Optional) SBS-AA,
<br /> inch inch dia.tin lap and 8-inch o.c. ACFoam II, Dens Deck SBS-AA, BP-AA,SBS- SBS-TA
<br /> Yosemite Venting
<br /> W-10 plywood at caps with 11 ga. in three(3),equally FlintBoard ISO, HA primed with HA -52.5
<br /> max.24- Base Sheet annular ring spaced,staggered ENRGY-3,H-Shield FlintPrime(ASTM SBS-TA or AA,SBS-TA or APP-
<br /> inch spans shank nails center rows or Multi-Max FA3 D41)primer APP-TA or APP-TA TA
<br /> Min.19/32- Glasbase,All 32 ga.,1-5/8- 8-inch o.c.in 3-inch (Optional)Min. HA full HA full
<br /> inch Weather Empire, inch dia.tin lap and 8-inch o.c. 1.5-inch ACFoam coverage or Min.0.25-inch coverege or BP-AA, (Optional) SBS-AA,
<br /> OB500,M- SECUROCK OB500,M- SBS-AA, BP-AA,SBS- SBS-TA
<br /> W-11 plywood at Flexiglas Base,Poly caps with 11 ga. in three(3),equally II,FlintBoard ISO, -60.0
<br /> max.24- SMS or Ultra Poly annular ring spaced,staggered ENRGY-3,H-Shield OSFA,A-PD, Gypsum-Fiber OSFA,A-PD,D- SBS-TA or AA,SBS-TA or APP-
<br /> inch spans SMS shank nails center rows or Multi-Max FA3
<br /> D-IS or CR-20, Roof Board IS or CR-20,6- APP-TA or APP-TA TA
<br /> 4-inch o.c. inch o.c.
<br /> Min.19/32- 32 ga.,1-5/8- 8-inch o.c.in 3-inch (Optional)Min. Min.0.25-inch BP-AA, (Optional) SBS-AA,
<br /> inch inch dia.tin lap and 8-inch o.c. 1.5-inch ACFoam
<br /> Yosemite Venting SECUROCK SBS-AA, BP-AA,5B5- SBS-TA
<br /> W-12 plywood at gase Sheet caps with 11 ga. in three(3),equally II,FlintBoard I50, HA Gypsum-Fiber HA SBS-TA or AA,SBS-TA or APP- -60.0
<br /> max.24- annular ring spaced,staggered ENRGY-3,H-Shield
<br /> inch spans shank nails center rows or Multi-Max FA3 Roof Board APP-TA or APP-TA TA
<br /> Exteriar Research and Design,LLC.d/b/a Trinity�ERD Evaluation Report 3520.03.04-R18 for FL2533-R37
<br /> Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/16/2017
<br /> Prepared by: Robert Nieminen,PE-59166 CertainTeed Corporation;(610)651-5847 Appendix 1,Page 6 of 57
<br />
|