Laserfiche WebLink
TRINIIY I ERD • <br /> TABLE 1C: WOOD DECKS—NEW CONSTRUCTION,REROOF(TeaR-OFF)oa RECOVER <br /> SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER � <br /> System Deck Top Insulation Layer Roof Cover(Note 14) MDP <br /> No. (Note 1) Base Insulation Layer Type Fasteners Attach Base Ply Cap (psf) <br /> Min.15/32-inch (Optional)Min.1.5-inch,One Min.1.5-inch ACFoam II, Flintfast 3 in.Insulation (Optional)SBS- <br /> W-27 plywood at max.24- or more layers,any FlintBoard ISO,H-Shield, Plates with FlintFast#12 1 per 1.33 ftZ SBS-SA-H AA,SBS-TA or SBS-AA,SBS-TA _�5.0 <br /> inch spans combination,loose laid FlintBoard ISO„ or#14 APP-TA or APP-TA <br /> Min.19/32-inch (Optional)One or more Min.1.5-inch ACFoam II, (Optional)SBS- SBS-TA or APP- <br /> W-28 exterior grade plywood layers,any combination, FlintBoard ISO,ENRGY 3 or Note 2 1 per 1.33 ftZ SBS-SA-H TA or APP-TA TA $z'S <br /> at max.24-inch spans loose laid Multi-Max FA3 <br /> CONVENTIONAL$YSTEMS: <br /> Min.23/32-inch (Optional)One or more Min.0.5-inch FM Approved (Optional)BP- <br /> W-29 exterior grade plywood layers,any combination, Wood Fiberboard,min.0.75- Note 2 1 per 2 ftZ BP-AA or 5B5-AA AA,SBS-AA,SBS- SBS-AA,SBS-TA _45.0* <br /> at max.24-inch spans loose laid inch FM Approved perlite TA or APP-TA or APP-TA <br /> Min.OZS-inch SECUROCK <br /> Min.15/32-inch (Optional)One or more FlintFast#12 or#14 HD BP-AA,SBS-AA, (Optional)BP- <br /> W-30 plywood at max.24- layers,any combination, Gypsum-Fiber Roof Board, With FlintFast 3" 1 per 2 ft2 SBS-TA or APP- AA,SBS-AA,SBS- SBS-AA,SBS-TA _45.0' <br /> inch spans loose laid Dens Deck or Dens Deck Insulation Plates TA TA or APP-TA or APP-TA <br /> Prime <br /> Min.15/32-inch (Optional for Recover)Min. FlintFast#12 or#14 HD (Optional)APP- <br /> W-31 plywood at max.24- 1.5-inch,One or more layers, Min.0.25-inch SECUROCK With FlintFast 3" 1 per 1.45 ftZ APP-TA APP-TA -60.0 <br /> inch spans any combination,loose laid Gypsum-Fiber Roof Board Insulation Plates TA <br /> (Optional for Concrete or <br /> Min.19/32-inch FlintFast#12 or#14 HD BP-AA,SBS-AA, (Optional)BP- <br /> Recover)Min.2-inch ACFoam Min.0.5-inch SECUROCK z SBS-AA,585-TA <br /> W-32 exterior grade plywood II,FlintBoard,H-Shield or Gypsum-Fiber Roof Board W�th FlintFast 3" 1 per 1.78 ft SBS-TA or APP- AA,SBS-AA,SBS- or APP-TA -60.0 <br /> at max.24-inch spans ENRGY 3,loose laid. Insulation Plates TA TA or APP-TA <br /> Min.15/32-inch (Optional for Recover)Min. FlintFast ti12 or#14 HD (Optional)APP- <br /> W-33 plywood at max.24- 1.5-inch,One or more layers, Min.0.25-inch SECUROCK With FlintFast 3" 1 per 133 ft� APP-TA APP-TA -67.5 <br /> inch spans any combination,loose laid Gypsum-Fiber Roof Board Insulation Plates TA <br /> Exterior Research and Design,LLC.d/b/a Trinity�ERD Evaluation Report 3520.03.04-R18 for FL2533-R17 <br /> Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/16/2017 <br /> Prepared by: Robert Nieminen,PE-59166 CertainTeed Corporation;(610)651-5847 Appendix 1,Page 9 of 57 <br />