My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18375
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18375
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/19/2017 9:51:58 AM
Creation date
12/19/2017 9:51:57 AM
Metadata
Fields
Template:
Building Department
Company Name
MAJESTIC OAKS
Building Department - Doc Type
Permit
Permit #
17-18375
Building Department - Name
NHC-FL 115 LLC
Address
3909 QUAKER RIDGE ST LOT 67
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Site Preparation <br /> POCKET PENETROMETER TEST ' � � <br /> Debris and organic material removed X <br /> ocket penetrometer tests are rounded down to psf Water drainage: Natural Swale Pad X Other <br /> ;ck here to declare 1000 Ib. soil X without testing. <br /> Fastening multi wide units <br /> X X X <br /> Floor: Type Fastener: Length: Spacing: <br /> Walls: Type Fastener: Length: Spacing: <br /> POCKET PENETROMETER TESTING METHOD Roof: Type Fastener: Length: Spacing: <br /> For used homes a min.30 gauge, 8"wide, galvanized metal strip <br /> 1. Test the perimeter of the home at 6 locations. will be centered over the peak of the roof and fastened with galv. <br /> roofing nails at 2"on center on both sides of the centeriine. <br /> 2. Take the reading at the depth of the footer. <br /> GBSkeI(weatherproofinq requiremenfl <br /> 3. Using 500 ib. increments,take the lowest <br /> reading and round down to that increment. I understand a properly installed gasket is a requirement of all new and used <br /> homes and that condensation, mold, meldew and buckled marriage walls are <br /> a result of a poorly installed or no gasket being installed. I understand a strip <br /> X X X of tape will not serve as a gasket. <br /> Installer's initials <br /> TORQUE PROBE TEST ' <br /> Type qasket Installed: <br /> �sults of the torque probe test is 276 inch pounds or check Pg. Between Floors Yes � <br /> f you are declaring 5'anchors without testing . A test Between Walls Yes <br /> ng 275 inch pounds or less will require 5 foot anchors. Bottom of ridgebeam Yes � <br /> A state approved lateral arm system is being used and 4 ft. i, <br /> anchors are allowed at the sidewall locations. I understand 5 ft weatherproofing I <br /> anchors are required at all centerline tie points where the torque test I <br /> reading is 275 or less and where the mobile home manufacturer may The bottomboard will be repaired and/or taped. Yes X . Pg. <br /> requires anchors with 4000 Ib holding capacity. Siding on units is installed to manufacturer's specifications. Yes,�_ <br /> Installer's initials Fireplace chimney installed so as not to allow intrusion of rain water. Yes NA <br /> 4LL TESTS MUST BE PERFORMED BY A LICENSED INSTALLER Miscellaneous <br /> Name Lionel Easler Skirting to be installed. Yes�No <br /> Dryer vent installed outside of skirting. Yes N/A X <br /> ;ted 3�29��7 Range downflow vent installed outside of skirting. Yes N/A X <br /> Drain lines supported at 4 foot intervals. Yes X <br /> Electrical crossovers protected. Yes NA <br /> Other : <br /> Electrical <br /> �lectrical conductors between multi-wide units, but not to the main power <br /> �is includes the bonding wire between mult=wide units. Pg. NA <br /> Installer verifies ail information given with this permit worksheet <br /> um �n4 is accurate and true based on the • <br /> manufacturer's installation instructions and or Rule 15C-1 &2 <br /> I sewer drains to an existing sewer tap or septic tank. Pg. <br /> Installer Signature 7 � Date 4/6/17 <br /> I potable water supply piping to an existing water meter,water tap, or other ,P • <br /> �t water supply systems. Pg. " <br /> �v <br />
The URL can be used to link to this page
Your browser does not support the video tag.