Laserfiche WebLink
7 � � <br />_ <br /> FORM R405-2014 � <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION� <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Hayden 4EH EI v Builder Name: DRH Express Ho es/ <br /> Street: ��Q 'LI ���I e �1 I �►�J��� Perm it Office: e�'�.fi���Q���1��� <br /> City,State,Zip: Zephyrhills, FL,-�']C�/ Permit Number: ���3 � <br /> Owner: `L`"� � �✓ Jurisdiction: (p �/(P� <br /> Design Location: FL,Tampa 9�/ County:: Pasco(Florida Climate Zone 2) <br /> �� r <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2614.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=11.0 1285.30 ftz <br /> b.Concrete Block-Int Insul, Exterior R=4.1 996.67 ftz <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ftz <br /> 4. Number of Bedrooms 5 d.N/A R= ftz <br /> 10.Ceiling Types (1541.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ftz <br /> 6. Conditioned floor area above grade(ftz) 2605 b.N/A R= ftz <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11 Ducts R ft2 <br /> 7. Windows(250.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 <br /> a. U-Factor: Dbl,U=0.34 210.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 41.0 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.052 ft. <br /> Area Weighted Average SHGC: 0.315 14.Hot water systems <br /> 8. Floor Types (1541 0 sqft.) Insulation Area a.Electric Cap:50 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ftz b. Conservation features <br /> b.Raised Floor R=19.0 437.00 ft2 None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Total Proposed Modified Loads: 78.39 pASS <br /> Glass/Floor Area: 0.096 <br /> Total Baseline Loads: 79.15 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �TKE�T9T <br /> this calculation are in compliance with the Florida Energy specifications covered by this ���� _ �0�, <br /> Code. calculation indicates compliance � ,,,, ' _�'.�� �t„ <br /> with the Florida Energy Code. ti rr�r,���;':;:;:;;��,;;'���"�`;, O <br /> PREPARED BY: L'Nk..�,�:.� Before construction is completed � ; "� '� � <br /> ►,•�' _��_`�?t: O <br /> DATE: i�-�-�6 this building will be inspected for � I`�f����" � <br /> compliance with Section 553.908 * � ° * <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. ,t,� �� <br /> with the Florida Energy Code. G�b y�'�� <br /> OWNER/AGEN BUILDING OFFICIAL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn,requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.050 Qn for whole house. <br /> 11/7/2016 10:00 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />