Laserfiche WebLink
r '' <br /> FORM R405-2014 <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000368 2517.6 138.21 259.93 .3402 7 <br /> HEATING SYSTEM � <br /> # System Type Subtype Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump None HSPF:8.2 41 kBtulhr 1 sys#1 <br /> COOLING SYSTEM <br /> # System Type Subtype Efficiency Capacity- Air Flow SHR Block Ducts <br /> 1 Central Unit None SEER:14 40 kBtu/hr 1200 cfm 0.75 1 sys#1 <br /> HOT WATER SYSTEM <br /> # S stem T e SubT e Location EF Ca Use SetPnt Conservation <br /> Y YP YP P <br /> 1 Electric None Gara e 0.95 50 gal 70 gal 120 deg � None <br /> 9 <br /> SOLAR HOT WATER SYSTEM <br /> I FSEC Collector Storage <br /> Cert # Company Name System Model# Collector Model# Area Volume FEF <br /> None None ftZ <br /> DUCTS <br /> / ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# <br /> U # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool <br /> 1 Attic 6 261 ft2 2nd Floor 45 ft2 Praposed Qn 2nd Floor ---cfm 130.3 cfm 0.05 0.60 1 1 <br /> TEMPERATURES <br /> Programable Thermostat:Y Ceiling Fans: <br /> Coolin r 1Jan r 1Feb r �Mar r 1A r Ma rX�Jun Jul (X�Au Se r �Oct r �Nov Dec <br /> Heating [X]Jan [X�Feb [X]Mar [ ]APr f �May [ ]Jun f�Jul [ I Au9 4�Sep [ ]Oct [X]Nov Dec <br /> Ventin [ ]Jan [ ]Feb [X]Mar [X]A r [ Ma [ ]Jun � Jul [ ]Au � Se [x]Oct [x]Nov Dec <br /> 11/7/2016 10:00 AM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 4 of 5 II <br />