a <br /> �aEgs'�F Manual S Compliance Report Job: <br /> QP q'� Date: Oct 10,2014 <br /> ; .�: �,a Entire House Bv: <br /> ,�;� <br /> �•�:� Progressive Air Systems <br /> �''���5.�a <br /> 5907 Dasher ct,Port Richey,FI 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> � • ' 9 i <br /> For: Dr Horton/Express <br /> Lot 24 Blk 1 Silverado, Zephyrhilis, FI <br /> • • • • � <br /> Design Conditions <br /> Outdoor design DB: 91.2°F Sensible gain: 32055 Btuh Entering coil DB: 76.4°F <br /> Outdoor design WB: 77.1 °F Latent gain: 4144 Btuh Entering coil WB: 63.2°F <br /> Indoor design DB: 75.0°F Total gain: 36199 Btuh <br /> Indoor RH: 50% Estimated airflow: 1367 cfm <br /> Manufacturer's Pertormance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NA042`*"*A+FB4CNP042 <br /> Actual airflow: 1367 cfm <br /> Sensible capacity: 32442 Btuh 101%of load <br /> Latent capacity: 6271 Btuh 151%of load <br /> Total capacity: 38713 Btuh 107%of load SHR: 84% <br /> • • • <br /> Design Conditions <br /> Outdoor design DB: 40.0°F Heat loss: 27149 Btuh Entering coil DB: 69.5°F <br /> Indoor design DB: 70:0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NA042**"A+FB4CNP042 <br /> Actual airflow: 1367 cfm <br /> Output capacity: 37299 Btuh 137%of load Capacity balance: 37 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1367 cfm <br /> Output capacity: 8.6 kW 108%of load Temp. rise: 18 °F <br /> The above equipment was selected in accordance with ACCA Manual S. <br /> .� wri htsoft� 2016-Nov-0412:07:56 <br /> �. 9 Right-Suite�Universal 2013 13.0.11 RSU18520 Page 1 <br /> �� ..\Wrightsoft Files\E�ress homes\Hayden-4EHB.rup Calc=MJ8 House faces: W <br />