� � <br /> Q��oa�ss�vF'0,� Manual S Compliance Report Da e: Oct 10,2014 <br /> s r Entire House Bv� <br /> :�;;�' � <br /> �•�:� Progressive Air Systems <br /> ����5,�� <br /> 5907 Dasher ct,Port Richey,FI 34668 Phone:727-847-3898 �Fax:727-815-3399 License:CAC033669 <br /> � • ' 9 • <br /> For: DR Horton/Express homes <br /> Lot 22 Blk 1 Silverado, Zephyrhills, FI <br /> • • • s s <br /> Design Conditions � <br /> Outdoor design DB: 91.2°F Sensible gain: 21334 Btuh Entering coil DB: 76.1°F <br /> Outdoor design WB: 77.1°F Latent gain: 2877 Btuh Entering coil WB: 63.0°F <br /> Indoor design DB: 75.0°F Total gain: 24211 Btuh <br /> Indoor RH: 50% Estimated airflow: 1000 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB030*""`A+FB4CNP030 <br /> Actual airflow: 1000 cfm <br /> Sensible capacity: 23532 Btuh 110%of load <br /> Latent capacity: 3786 Btuh 132%of load <br /> Total capacity: 27318 Btuh 113%of load SHR: 86% <br /> • • • <br /> Design Conditions <br /> Outdoor design DB: 40.0`F Heat loss: 20312 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB030"'""A+FB4CNP030 <br /> Actual airflow: 1000 cfm <br /> Output capacity: 25625 Btuh 126%of load Capacity balance: 37 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1000 cfm <br /> Output capacity: 6.4 kW 108%of load Temp. rise: 20 °F <br /> The above equipment was selected in accordance with ACCA Manual S. <br /> �- wri htsoft� 2016-Nov-0412:29:46 <br /> �A� 9 Right-SuiteC�Universal 2013 13.0.11 RSU18520 Pa e 1 <br /> 9 <br /> .on\Wrightsoft Files\E�ress homesVlria 4EAB.rup Calc=MJ8 House faces: W <br />