Laserfiche WebLink
' J Manual S Com liance Re ort Job: 3711sfADS <br /> P P Date: 1213012016 <br /> upper floor By: Dave <br /> Bayonet Plumbing Heating and Cooling <br /> ' e - � • <br /> For: Lennar Homes <br /> • . • • . <br /> Design Conditions , <br /> Outdoor design DB: 91.3°F Sensible gain: 20703 Btuh Entering coil DB: 75.7°F <br /> Outdoor design WB• 77.3°F Latent gain: 1859 Btuh Entering coil WB 62.9°F <br /> Indoor design DB: 75.0°F Total gain: 22563 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 cfm <br /> i Manufacturer's Performance Data atActual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-024-230-18+CBX27UH-024-230"++TDR <br /> Actual airflow• 800 cfm <br /> Sensible capacity. 21420 Btuh 103% of load <br /> Latent capacity: 3780 Btuh 203% of load <br /> Total capacity: 25200 Btuh 112% of load SHR: 85% <br /> • . . <br /> Design Conditions <br /> Outdoor design DB 30.8°F Heat loss• 18942 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB. 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-024230-18+CBX27UH-024-230*++TDR <br /> Actual airflow: 800 cfm <br /> Output capacity: 21800 Btuh 115% of load Capacity balance: 35 °F , <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 800 cfm <br /> Output capacity• 6.0 kW 108% of load Temp. rise: 50 °F <br /> The above equipment was selected in accordance with ACCA Manual S. <br /> °�- wri htsoft� 2016-Dec-3013:53:05 <br /> � � 9 Right-Suite�Universel 2D13 13.0.09 RSU05714 Pa e 2 <br /> 9 <br /> �'� H:\LENNAR LOADS\3711 sf ADS drawn 2-2tons.rup Calc=MJB Front Door faces: N <br />