My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18393
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18393
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/19/2017 10:05:04 AM
Creation date
12/19/2017 10:05:02 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18393
Building Department - Name
LENNAR HOME SLLC
Address
6569 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L ' _ � <br /> FORM R405-2014 <br /> I <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 3711 SF Builder Name. LENNAR HOMES <br /> street: 6569 Silverado Ranch Boulevard Permit Office: Clty of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number: �g 3 93 <br /> Owner• LENNAR HOMES .lurisdiction: 611600 <br /> Design Location: FL,Tampa <br /> 1. New construction or existing New(From Plans) 9. Wall Types(3424.9 sqft.) Insulation Area <br /> a. Frame-Wood,Exterior R=11.0 1738.70 ftZ <br /> 2. Single family or multiple family Single-family b.Concrete Block-Int Insul, Exterior R=4.1 1487.10 ftz <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 199.11 ftz <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2130.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30 0 1998.00 ft <br /> 6. Conditioned floor area above grade(ftZ) 3711 b.Knee Wall(Vented) R=30.0 132.00 ftz <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11.Ducts R ftz <br /> 7. Windows(358.9 sqft.) Description Area a.Sup: 1st Floor, Ret: 1st Floor,AH: 1st Floor 6 525 <br /> a. U-Factor: Dbl, U=0.56 133.00 ftz b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 430 <br /> SHGC� SHGC=0.28 <br /> b. U-Factor• Dbl,U=0.54 119.25 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC� SHGC=0.31 a.Central Unit 25.2 SEER:16.20 <br /> b.Central Unit 25.2 SEER:16.20 <br /> c. U-Factor• Dbl, U=0.56 106.67 ft2 <br /> SHGC� SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 21.8 HSPF:9.00 <br /> SHGC� b. Electric Heat Pump 21.8 HSPF:9.00 <br /> Area Weighted Average Overhang Depth: 2.938 ft. <br /> Area Weighted Average SHGC: 0.302 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (1986.0 sqft.) Insulation Area EF.0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1713.00 ftz b. Consenration features <br /> b.Floor over Garage R=11.0 273.00 ftZ None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.097 <br /> Total Proposed Modified Loads: 97.04 pASS <br /> Total Baseline Loads: 98.86 <br /> I hereby certify that the plans and specifications covered by Review of the plans and _��'���"�'.Q�� • I <br /> this calculation are in compliance with the Florida Energy specifications covered by this 1� ,� ��� O�, <br /> Code. calculation indicates compliance ��,,;�'` "= '.�` �. <br /> +�;, __ ` •,,� .�C`. <br /> /,, with the Florida Energy Code. " �^+ fr�fr�,"�'��a:�;:;;:"�;���,ti Q <br /> PREPARED BY' `�QVe �����'c Before construction is completed , � <br /> this buildin will be ins ected for � ''"`� '' � Q <br /> DATE. 9 P c9 ' ����� � <br /> compliance with Section 553.908 * • � '� <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. �C <br /> Y fY 9� 9 P ��;Q..':':.. �j� <br /> with the Florida Energy Code. ,( D WE'� ,. <br /> OWNER/AGENT. BUILDING OF ICIAL. ` <br /> DATE: � � DATE: <br /> - Compliance requires certification by.the air handler unit manufacturer that the air handler enclosure qualifies as , <br /> certified factory-sealed in accordance with R403.2.2.1. ' <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> 12/30/2016 2:05 PM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.