Laserfiche WebLink
� ,. <br /> FORM 1�405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION � <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 3711 SF Builder Name: LENNAR HOMES <br /> street: 6569 Silverado Ranch Boulevard Permit office: City of Zephyrhills <br /> City,State,Zip. ,FL, Permit Number� <br /> Owner• LENNAR HOMES .lurisdiction: 611600 <br />� Design Location: FL,Tampa <br /> 1. New construction or existing New(From Plans) 9. Wall Types(3424.9 sqft.) Insulation Area � <br /> 2. Single family or multiple family Single-family a. Frame-Wood,Exterior R=11.0 1738.70 ftz <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1487.10 ftz <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 199.11 ft2 <br /> 4. Number of Bedrooms 4 ' d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2130.0 sqft.) Insulation Area 2 <br /> a. Under Attic(Vented) R=30.0 1998.00 ft <br />, 6. Conditioned floor area above grade(ftz) 3711 b. Knee Wall(Vented) R=30.0 132.00 ft2 <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ftz <br /> 11 Ducts R ft2 <br /> 7. Windows(358.9 sqft.) Description Area a.Sup: 1st Floor, Ret: 1st Floor,AH: 1st Floor 6 525 <br /> a. U-Factor• Dbl,U=0.56 133.00 ftz b.Sup• Attic, Ret:2nd Floor,AH:2nd Floor 6 430 <br /> SHGC� SHGC=0.28 ' <br /> b. U-Factor� Dbl, U=0.54 119.25 ft� 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.31 a.Central Unit 25.2 SEER:16.20 <br /> b.Central Unit 25.2 SEER:16.20 <br /> c. U-Factor• Dbl, U=0.56 106.67 ftz <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a. Electric Heat Pump 21.8 HSPF:9.00 <br /> SHGC: b. Electric Heat Pump 21.8 HSPF:9.00 <br /> Area Weighted Average Overhang Depth: 2.938 ft. <br /> Area Weighted Average SHGC: 0.302 14 Hot water systems <br /> a.Electric Cap•40 gallons <br /> 8. Floor Types (1986.0 sqft.) Insulation Area EF.0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1713.00 ft2 b. Conservation features <br /> b.Floor over Garage R=11.0 273.00 ftz None <br /> c. N/A R= ftZ 15.Credits Pstat <br /> Glass/Floor Area: 0.097 Total Proposed Modified Loads: 97.04 pASS <br /> Total Baseline Loads: 98.86 <br /> I hereby certify that the plans and specifications covered by Review of the plans and • ,��'t.�,j�"T,tq�,� . <br /> this calculation are in compliance with the Florida Energy specifications covered by this 1� ;� =.�` O�, . <br /> Code. calculation indicates compliance �'�r,,;'' `�=,:.,? vs'� <br /> r�;� �;..a� .,� . <br /> �ave ��w��G� wi t h t he F lori da Energy Co de. � rrrrr�`�'%;::�_��;,,��,� .a <br /> .r, cr..e.�,.� <br /> PREPARED BY' �� Before construction is completed � <br /> DATE: this building will be inspected for � - ��f�{: ;� <br /> compliance with Section 553.908 � ��� (-� � . � <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. �. <br /> Y fY 9, 9 P '��1r�, . - . ��S <br /> with the Florida Energy Code. �D'y�Ti`1�' <br /> OWNER/AGENT� BUILDING OFFICIAL. <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. � <br /> 12/30/2016 2:05 PM EnergyGaugeO USA-FlaRes2014 Section R405 4.1 Compliant Software Page 1 of 5 <br />