My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18394
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18394
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/19/2017 10:06:03 AM
Creation date
12/19/2017 10:06:01 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18394
Building Department - Name
LENNAR HOMES LLC
Address
6528 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
\ <br /> ., s <br /> . FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2268 sf ADS Builder Name: LENNAR HOMES <br /> street: 6528 Paden Wheel Street Pe������ Cl of Zephyrhills <br /> City,State,Zip. ,FL, Pertnit Number c� <br /> Owner LENNAR HOMES Jurisdiction: C1�( Q3 � <br /> Design Location: FL,Tampa <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2268.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family - a.Concrete Block-Int Insul,Exterior R=4 1 1904.00 ftZ <br /> b.Frame-Wood,Adjacent R=11.0 364.00 ft' <br /> 3. Number of units,if multiple family 1 c.N/A R= ft' <br /> 4. Number of Bedrooms 4 d.N/A R= ft' <br /> 10.Ceiling Types (2267.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2267.00 ftZ <br /> 6. Conditioned floor area above grade(ft2) 2267 b.N/A R= ft' ' <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ft' <br /> 11 Ducts R ftZ <br /> 7. Windows(277.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 600 <br /> a. U-Factor: Dbl,U=0.54 143.00 ft' _ <br /> SHGC: SHGC=0.31 i <br /> ` b. U-Factor Dbl,U=0.58 96.00 ft2 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.20 <br /> c. U-Factor• Dbl,U=0.56 38.00 ft= _ <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> i d. U-Factor N/A ftZ a.Electric Heat Pump 32.8 HSPF:8.70 � <br /> SHGC: <br /> Area Weighted Average Overhang Depth. 4.206 ft. <br /> Area Weighted Average SHGC: 0.309 14 Hot water systems <br /> 8. Floor Types (2267.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2267.00 ftz b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> Total Proposed Modified Loads: 71.00 pASS <br /> Glass/Floor Area. 0.122 <br /> Total Baseline Loads: 72.50 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �'��s�'��, <br /> this calculation are in compliance with the Florida Energy specifications covered by this �,� �� r"_.�.��0�,, . <br /> Code. calculation indicates compliance �'�r,,,;'' "_:=�'��`. � <br /> ,{/,,� /. with the Florida Energy Code. �+ ?rr�r,�'.%r;;`;�'�;�.,��;,,��O. <br /> PREPARED BY. �av� r�fWl{'I�VG Before construction is completed w ��E` '' - " � <br /> DATE. this building will be inspected for i�,ry ���.��';` " ;��� <br /> ' compliance with Section 553.908 * �"� - <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. �,� ",. � ���� <br /> i with the Florida Energy Code. � ��U�Wfl`� <br /> � OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct�leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 3/17/2017 7�48 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.