Laserfiche WebLink
i' �r <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2386 sf ADS Builder Name: Lennar Homes <br /> street: 36092 Stable Wilk Avenue � Perr„�c offi�e: Gity of 7� hyrhills <br /> City,State,Zip: ,FL, Permit Number: ?J y�� <br /> Owner• Lennar Homes Jurisdiction: 611�0� <br /> Design Location: FL,Tampa <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2570.5 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1285.70 ftZ <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1118.00 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 166.83 ft2 <br /> 4 Number of Bedrooms 5 d.N/A R= ftz <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1272.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1120.00 ft2 <br /> 6. Conditioned floor area above grade(ft� 2389 b.Knee Wall(Vented) R=30.0 152.00 ftZ <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftz <br /> 11.Ducts R ftZ <br /> 7. Windows(168.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 477.8 <br /> a. U-Factor• Dbl,U=0.54 96.00 ftz „ <br /> SHGC• SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 38.68 ftZ 12.Cooling systems kBtu/hr Efficiency <br /> SHGC• SHGC=0.28 a.Central Unit 43.5�SEER:15.50 <br /> c. U-Factor• Dbl,U=0.56 33.33 ftZ <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor� N/A ftZ a.Electric Heat Pump 43.5 HSPF:9.00 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.000 ft. <br /> Area Weighted Average SHGC• 0.305 14.Hot water systems <br /> 8. Floor Types (1269.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1269.00 ftZ b. Conservation features <br /> b N/A R= ftZ None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> Glass/FloorArea. 0.070 Total Proposed Modified Loads. 67.32 pASS <br /> Total Baseline Loads: 69.61 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �'C�E?T,q�, <br /> � ' � : ;. � . ' <br /> this calculation are in compliance with the Florida Energy specifications covered by this 'b�,���,� �^�` +p� . <br /> Code. calculation indicates compliance ��.r,,;� -�a��.w�� ,��,. <br /> with the Florida Energy Code. �+. +nr�,.��%,":_:;';�°<.�„ O� . <br /> J7aV2 ��O�YlG�I . ,�� ��,,;:� <br /> PREPARED BY Before construction is completed � �}� � <br /> DATE: this building will be inspected for t;ry :''� � <br /> t :� <br /> compliance with Section 553.908 * ° ;, <br /> I hereby certify that this building,as designed, ' in compliance Florida Statutes. 1,i; � ", � ��, <br /> with the Florida Energy Code. �'C)jj yy�'��` <br /> OWNER/AGENT. � BUILDING OFFIC AL. L�' <br /> DATE: I DATE: <br /> - Compliance requires certification b the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 12/30/2016 12:15 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />