My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18395
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18395
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/19/2017 10:07:04 AM
Creation date
12/19/2017 10:07:02 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18395
Building Department - Name
LENNAR HOMES LLC
Address
36092 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 \ <br /> FORM R405-2014 <br /> WALLS <br /> Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w <br /> 1 N=>NE Exterior Concrete Block-Int Insul 1st Floor 4.0999 10 8 8 86.7 ftZ 0 0.600000 0 <br />' 2 E=>SE Exterior Concrete Block-Int Insul 1 st Floor 4.0999 52 8 8 450.7 ft� 0 0.600000 0 <br /> 3 S=>SW Exterior Concrete Block-Int Insul 1st Floor 4.0999 30 8 8 260.0 ft� 0 0.600000 0 <br /> 4 W=>NW Exterior Concrete Block-Int Insul 1st Floor 4.0999 37 B 8 320 7 ftz 0 0.600000 0 <br /> _ 5 N=>NE Garage Frame-Wood 1st Floor 11 19 3 8 8 166.8 ftZ 0 0.01 0 <br /> 6 W=>NW Exterior Frame-Wood 1 st Floor 11 14 6 8 8 125.7 ftZ 0 0.01 0 <br /> 7 N=>NE Exterior Frame-Wood 2nd Floor 11 18 6 8 148.0 ft2 0 0.600000 0 <br /> 8 E=>SE Exterior Frame-Wood 2nd Floor 11 52 8 416.0 ft2 0 0.600000 0 <br /> 9 S=>SW Exterior Frame-Wood 2nd Floor 11 30 B 240.0 ftZ 0 0.600000 0 <br /> 10 W=>NW Exterior Frame-Wood 2nd Floor 11 44 6 B 356.0 ftZ 0 0.600000 0 <br /> DOORS <br /> # Ornt Door Type Space Storms U-Value Width Height Area � <br /> Ft In Ft In <br /> 1 N=>NE Insulated 1st Floor None .2 3 6 8 20 ftZ <br /> 2 N=>NE Wood 1st Floor None .4 2 8 6 8 17.8 ft2 <br /> WINDOWS <br /> Orientation shown is the entered orientation => chan ed to Worst Case. <br /> � Wall Overhang <br /> # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening <br /> 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 6.7 ft2 1 ft 0 in 10 ft 4 in Drapes/blinds None <br /> 2 E=>SE 2 Metal Low-E Double Yes 0.54 0.31 16.0 ftZ 1 ft 0 in 10 ft 4 in Drapes/blinds None <br /> 3 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 16.0 ftz 1 ft 0 in 10 ft 4 in Drapes/blinds None <br /> 4 S=>SW 3 Metal Low-E Double Yes 0.56 0.32 33.3 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds None <br /> 5 N=>NE 7 Metal Low-E Double Yes 0.56 0.28 16.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None <br /> 6 E=>SE 8 Metal Low-E Double Yes 0.54 0.31 16.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds None <br /> 7 S=>SW 9 Metal Low-E Double Yes 0.54 0.31 16.0 ftx 1 ft 0 in 0 ft 6 in Drapes/blinds None <br /> 8 W=>NW 10 Metai Low-E Double Yes 0.54 0.31 32.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds None <br /> 9 N=>NE 7 Metal Low-E Double Yes 0.56 0.28 16.0 ftZ 1 ft 0 in 3 ft 0 in None None <br /> GARAGE <br /> # FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 414 ft2 384 ft2 45 ft 8.6 ft 1 <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000264 1656.1 90.92 170.99 .244 5 <br /> 12/30/2016 12:15 PM EnergyGaugeB USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.