Laserfiche WebLink
., ; <br /> Manual S Compliance Report Job: 1941 sfADS <br /> Date: 12/30I2016 <br /> En fire Ho use By: Dave <br /> � BAYONET PLUMBING COOLING HEATING <br /> ' � - � • <br /> For: Lennar Homes <br /> � � e � � <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 26128 Btuh Entering coil DB: 75.6°F <br /> Outdoor design WB: 77.3°F Latent gain: 4093 Btuh Entering coil WB 62.8°F <br /> Indoor design DB. 75.0°F Total gain: 30222 Btuh <br /> Indoor RH: 50% Estimated airflow� 1200 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type. SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-036-230-18+CBX27UH-036-230*++TDR <br /> Actual airtlow: 1200 cfm <br /> Sensible capacity: 29580 Btuh 113% of load <br /> Latent capacity� 5220 Btuh 128% of load <br /> Total capacity: 34800 Btuh 115% of load SHR: 85% <br /> . . • <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss. 28865 Btuh Entering coil DB: 69.7°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Lennox Model: 14HPX-036-230-18+CBX27UH-036-230*++TDR <br /> Actual airflow: 1200 cfm <br /> Output capacity• 32800 Btuh 114°/a of load Capacity balance. 35 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+n/a <br /> Actual airflow: 1200 cfm <br /> Output capacity: 0 kW 0% of load Temp. rise: 0 °F <br /> The above equipment was selected in accordance with ACCA Manual S. <br /> ... wri htsoft�` 2016-Dec-30 08:47:09 <br /> �..._ 9 Right-Suite�Universal 2013 13.0.09 RSU05714 Page 1 <br /> �'� H:\LENNAR LOADS\1941 sf ADS 3ton.rup Calc=MJ8 Front Door faces: S <br />