Laserfiche WebLink
T '� <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 3127 sf ADS Builder Name: LENNAR HOMES <br /> street: 6564 Paden Wheel Street Permit Office: Cl o Zephyrhills <br /> City,State,Zip: ,FL, Permit Number ����' <br /> Owner• LENNAR HOMES Jurisdiction: 611600 <br /> Design Location: FL,Tampa <br /> 1 New construction or existing New(From Plans) 9 Wall Types(2907.1 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1389.30 ftZ <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1309.80 ftz <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 208.00 ftz <br /> 4 Number of Bedrooms 5 d.N/A R_ ftZ <br /> 10 Ceiling Types (1946.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1772.00 ftZ <br /> 6. Conditioned floor area above grade(ftz) 3127 b.Knee Wall(Vented) R=30.0 174.00 ft� <br /> Conditioned floor area below grade(ftZ) 0 c. A R= ft <br /> z <br /> 11.Ducts R ftz <br /> 7. Windows(366.3 sqft.) Description Area a.Sup•Attic,Ret:1st Floor,AH:1st Floor 6 585 <br /> a. U-Factor Dbl,U=0.54 162.68 ftz b.Sup• Attic,Ret:2nd Floor,AH:2nd Floor 6 545 <br /> SHGC• SHGC=0.31 <br /> b. U-Factor� Dbl,U=0.56 117.00 ft� 12.Cooling systems kBtu/hr Efficiency <br /> SHGC• SHGC=0.28 a.Central Unit 25.2 SEER:16.20 <br /> b.Central Unit 25.2 SEER:16.20 <br /> c. U-Factor Dbl,U=0.56 86.67 ft2 <br /> SHGC� SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor� N/A ftz a.Electric Heat Pump 21.8 HSPF:9.00 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:9.00 <br /> Area Weighted Average Overhang Depth: 4.213 ft. <br /> Area Weighted Average SHGC� 0.303 14 Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (1772.0 sqft.) Insulation Area EF•0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ft2 b. Conservation features <br /> b Floor over Garage R=11.0 '260.00 ftZ None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> Total Proposed Modified Loads: 91.14 PASS <br /> Glass/Floor Area: 0.117 Total Baseline Loads: 90.86 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��'���T.q�, <br /> this calculation are in compliance with the Florida Energy specifications covered by this �4, . '" w,- ,��j <br /> Code. calculation indicates compliance �'��rf,��''' , ,:_`�4,r.� <br /> ti�+'�'` <br /> �ave ���G� with the Florida Energy Code. � rarrr° �''� •--��';�Y,��'�,c„ti O <br /> PREPARED BY: Before con`struction is completed v� �:-, '�'"�� '`"_" ''�t-�' <br /> DATE: this building will be inspected for � ' -' 7=�` _ ;� <br /> �'�--�.:.. <br /> compliance with Section 553.908 ,, • � � <br /> I hereb certi that this buildin as desi n , is in com liance Florida Statutes. } . : ` � .�. <br /> Y fY 9, 9 P �1+ ' �s: . <br /> with the Florida Energy Code. `�''Ojj ySrg''�� <br /> OWNER/AGENT: BUILDING QFFIL�I � <br /> DATE. DATE. 'L'4� <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 1/3/2017 12:24 PM EnergyGauge�USA-FlaRes2014 Section R405 4 1 Compliant Software Page 1 of 5 <br /> �� <br /> , .\ <br />