Laserfiche WebLink
Manual S Compliance Report Job: 3127sf <br /> Date: 113/2017 <br /> lowerfloor ' By: DaveAldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> � i ' � � <br /> For: Lennar Homes • <br /> � � e • • <br /> Design Conditions � <br /> Outdoor design DB. 91.3°F Sensible gain: 19283 Btuh Entering coil DB. 75.6°F <br /> Outdoor design WB• 77.3°F Latent gain: 2611 Btuh Entering coil WB. 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 21894 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 cfm <br /> Manufacturer's Performance Data atActual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-024-230-18+CBX27UH-024-230'++TDR <br /> Actual airflow: 800 cfm <br /> Sensible capacity: 21420 Btuh 111% of load <br /> Latent capacity: 3780 Btuh 145% of load <br /> Total capacity� 25200 Btuh 115% of load SHR. 85% <br /> o e e <br /> Design Conditions <br /> Outdoor design DB• 30.8°F Heat loss: 24170 Btuh Entering coil DB. 69.6°F <br /> Indoor design DB: 70.0°F � <br /> Manufacturer's Performance Data atActual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-024230-18+CBX27UH-024-230"++TDR <br /> Actual airflow: 800 cfm <br /> Output capacity: 21800 Btuh 90% of Ioad Capacity balance: 40 °F <br /> , Supplemental heat required: 2370 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow• 800 cfm <br /> Output capacity: 7.1 kW 100% of load Temp. rise: 50 °F <br /> The above equipment was selected in accordance with ACCA Manual S. <br /> .•.. wri htsoft` 2017-Jan-0311:34:04 <br /> � 9 Right-Suite�Universal 2013 13.0.09 RSU05714 Page 1 <br /> �'�H:\LENNAR LOADS\3127 sf ADS 2-2fons.rup Calc=MJB Front Door faces:SW <br />