Laserfiche WebLink
Y 1 <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2575 sf ADS B elv Builder Name: Lennar Homes <br /> street: 36101 Stable Wilk Avenue Permit Office: Cl���ephyrhills <br /> City,State,Zip: ,FL, Permit Number � <br /> Owner Lennar homes Jurisdiction: 61�6�� <br /> Design Location: FL,Tampa <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2613.8 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1273.30 ftz <br /> b.Concrete Block-Int Insul,Exterior R=4.1 988.00 ft' <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft' <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area 2 <br /> a.Under Attic(Vented) R=30.0 1489.00 ft <br /> 6. Conditioned floor area above grade(ftz) 2582 b.N/A R= ftZ <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ <br /> 11 Ducts R ftZ <br /> 7. Windows(129.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 258.4 <br /> a. U-Factor• Dbl,U=0.54 48.25 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 258.4 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 48.00 ft' 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:I6.OD <br /> b.Central Unit 25.2 SEER:16.20 <br /> c. U-Factor Dbl,U=0:56 33.33 ft' . <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A ftZ a.Electric Heat Pump 17.5 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:9.00 <br /> Area Weighted Average Overhang Depth: 1.000 ft. <br /> Area Weighted Average SHGC: 0.301 14 Hot water systems <br /> 8. FloorTypes (1499.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ftz b. Conservation features <br /> b.Raised Floor R=11.0 406.00 ft' None <br /> c.N!A R= ftz 15.Credits Pstat <br />' Total Proposed Modified Loads: 66.18 <br /> Glass/Floor Area. 0.050 � <br /> Total Baseline Loads. 69.70 PASS <br /> I hereby certify that the plans and specifications covered by Review of the plans and ;��'��T�x� <br /> this calculation are in compliance with the Florida Energy specifications covered by this �4, , �`�' _ � ,; 0,�, <br /> Code. calculation indicates compliance ��_,,,°,''?` 4`^- 4�ti���� <br /> /. with the Florida Energy Code. � �rr;,,�'�%,`.,;��_�;``.��,,,ti O� <br /> PREPARED BY: �a�e ����V` Before construction is completed r�. �; � � <br /> DATE. this building will be inspected for � f�'�'" ..F k:� <br /> •,11: .,� <br /> - - compliance with Section 553.908 . � <br /> I hereb certi that this buildin as desi ned��is in com liance Florida Statutes. t,,�,,. _ � <br /> Y fY 9� 9 � P .�. <br /> �' . <br /> with the Florida Energy Code. �D:yyE`� <br /> OWNER/AGENT. BUILDING OFFICIAL. <br />� DATE. DATE: � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. � <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 3/17/2017 8:07 AM EnergyGauge�USA-FlaRes2014 Section R4�5.4.1 Compliant Software Page 1 of 4 <br />