Laserfiche WebLink
r � <br /> I FORM R405-2014 <br /> F�ORIDA ENERGY EFFICIENCY COD� FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name. 2575 sf ADS B elv Builder Name: Lennar Homes <br /> street: 36101 Stable Wilk Avenue Permit o�ice: City of Zephyrhills <br /> - City,State,Zip: ,FL, Permit Number <br /> Owner• Lennar homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa <br /> 1 New construction or existing New(From Plans) 9. Wall Types(26,13.8 sqft.) Insulation Area <br /> a.Frame-Wood,Exterior R=11.0 1273.30 ft� <br /> 2. Single family or multiple family Single-family b.Concrete Block-Int Insul,Exterior R=4.1 988.00 ft� <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft' <br /> 4 Number of Bedrooms 4 d.N/A R= ftZ <br /> 10.Ceiling Types (1489.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1489.00 ftZ <br /> 6. Conditioned floor area above grade(ft2) 2582 b.N/A R= ftZ <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ <br /> 11.Ducts R ft2 <br /> 7. Windows(129.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 258.4 <br /> a. U-Factor• Dbl,U=0.54 48.25 ft' b.Sup: Attic, Ret:2nd Floor,AH:2nd Floor 6 258.4 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 48.00 ft' �2•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.20 <br /> c. U-Factor• Dbl,U=0.56 33.33 ftZ <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N!A ft2 a.Electric Heat Pump 17.5 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:9.00 <br /> Area Weighted Average Overhang Depth: 1.000 ft. <br /> Area Weighted Average SHGC: 0.301 14.Hot water systems <br /> 8. Floor Types (1499.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features <br /> b.Raised Floor R=11.0 406.00 ftz None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> Glass/Floor Area: 0.050 Total Proposed Modified Loads: 66.18 pASS <br /> Total Baseline Loads: 69 70 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �'C�.�T.qr. <br /> this calculation are in compliance with the Florida Energy specifications covered by this ti�; , � �t,7,, <br /> ' Code. calculation indicates compliance �'��,,,�;`' r=;:''�.�`- �. <br /> �s�'% •.:�::`��� 5\l i <br /> r" <br /> /. with the Florida Energy Code. � �rrr�t•- °�.�.;.:�,..�,�,,,•� <br /> PREPARED BY' �a�� �����'` Before construction is completed c��"r��"' :' .» <br /> DATE: this building will be inspected for � >'''$�}" - � <br /> #41. <br /> compliance with Section 553.908 $ �"� "� <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. :� . ", " ����. <br /> �r, <br /> with the Florida Energy Code. I?ytf;F,',�' <br /> OWNER/AGENT: BUILDING FFICIAL. <br /> DATE: DATE: ' <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 3/17/2017 8:07 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />