My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18369
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18369
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/1/2018 11:17:41 AM
Creation date
5/1/2018 11:17:39 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18369
Building Department - Name
D R HORTON INC
Address
36161 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> Q��°'�ss'"F�,, Load �Shor� Form Job: <br /> Date: Oct 10,2014 <br /> l Entire House By: <br /> :�.�- .�n <br /> ���: Progressive Air Systems <br /> S'�+�MS.�•► <br /> 5907 Dasher ct,Port Richey,FI 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> � � ' 9 � <br /> For: DR Horton/Express <br /> Lot 23 Blk 1 Silverado, Zephyrhiils, FI <br /> � - � • • <br /> Htg Clg Infiltration <br /> Outside db(°F) 40 91 Method Simplified <br /> Inside db(°F) 70 75 Construction quality Semi-tight <br /> Design TD (°F) 30 16 Fireplaces 0 <br /> Daily range - L <br /> Inside humidity (%) 50 50 <br /> Moisture difference(gr/Ib) 26 54 <br /> HEATING EQUIPMENT COOLING EQUIPMENT <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model CH14NA030****A Cond CH14NA030**""A <br /> AHRI ref 6804001 Coil FB4CNP030 <br /> AHRI ref 6804001 ' <br /> Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER I� <br /> Heating input Sensible cooling 22500 Btuh <br /> Heating output 29600 Btuh @ 47°F Latent cooling 7500 Btuh <br /> Temperature rise 27 °F Total cooling 30000 Btuh <br />� Actual air flow 1000 cfm Actual air flow 1000 cfm <br /> Air flow factor 0.047 cfm/Btuh Air flow factor 0.048 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.88 <br /> ROOM NAME Area Htg load Clg load Htg AVF Clg AVF <br /> (ft2) (Btuh) (Btuh) (cfm) (cfm) <br /> � M bed 194 3196 3104 151 149 <br /> living room 270 2891 3627 137 174 <br /> kitchen/dining 349 4292 5088 203 244 <br /> bed3 155 1420 1098 67 53 <br /> bath2 55 604 278 29 13 <br /> bed2 168 3411 3268 162 156 <br /> wc 21 24 35 1 2 <br /> M bath 114 1276 652 60 31 <br /> M wic 66 77 112 4 5 <br /> laundry 39 45 668 2 32 <br /> bed4/den opt 169 1866 1306 88 63 <br /> A/C closet 19 181 •114 9 5 <br /> foyer 200 1817 1542 86 74 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br />' .� wri htsoft° 2016-Nov-04 12:21:58 <br /> A� 9 Right-Suite�Universal 2013 13.0.11 RSU18520 Page 1 <br /> � .on\Wrightsoft Files\Express homes\Cali 4EBB.rup Calc=MJ8 House faces: W <br />
The URL can be used to link to this page
Your browser does not support the video tag.