Laserfiche WebLink
r( % � <br /> i t`�-� <br /> ` __ <br /> � s'�—f�li�fl�'�E�D <br /> 4.3 Accessorv Starter Striqs: <br /> 4.3.1 Pro-Start� Eave/Rake Starter Strip Shingles and WeatherBlocker`"" Premium Eave/Rake 5tarter 5trip Shingles <br /> are starter strips for asphalt roof shingles. � <br /> 4.3.2 QuickStartm Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS <br /> modified bitumen starter strip, nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of 6- <br /> inch or less. <br /> 4.3.3 StarterMatchT"" Sharter Strip Shingles are color-coordinated starter strips for use with Grand Canyon`� and <br /> Grand Sequoiaa' series asphalt shingles. StarterMatchiM are installed as the second starter for Grand <br /> Canyon°and Grand Sequoia°series installations. <br /> 5. LIMITATIONS: <br /> 5.1 This is a building code evaluation. Neither Trinity�ERD nor Robert Nieminen, P.E. are, in any way, the <br /> � Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was <br /> used for permitting or design guidance unless retained specifically for that purpose. <br /> 5.2 This Evaluation Report is not for use in the HVHZ. <br /> 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials <br /> Directory for fire ratings of this product. <br /> 5.4 Wind Classification: <br /> 5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and <br /> R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for <br /> use in all wind zones up to V,�=150 mph (V���=194 mph). Refer to Section 6 for installation requirements <br /> to meet this wind rating. <br /> 5.4.2 The GAF hip &ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 <br /> and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for use in all wind zones up to <br /> Va,d=150 mph(V�it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. <br /> 5.4.3 Classification by ASTM D7158 applies only to exposure category B or C, as deFined in FBC 1609.4.3, and a <br /> mean roof height of 60 feet or less. Calculations by a qualified design professional are required for <br /> conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. <br /> 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building <br /> Code and F.A.C.Rule 61G20-3. <br /> 6. INSTALLATION: <br /> 6.1 Underlayment: <br /> 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be <br /> Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. <br /> 6.2 Starter Shingles or Starter Strip: <br /> 6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles, WeatherBlocker Premium Eave/Rake Starter Strip <br /> Shingles and QuickStart Peel&Stick Starter Roll shall comply with the GAF current published instructions. <br /> 6.3 Asphalt Shingles: <br /> 6.3.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using <br /> minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905,2, with the following <br /> exceptions: <br /> i Camelot, Camelot II, Grand Canyon,Grand Sequoia,Grand Sequoia lR, Grand Sequoia ArmorShield,and <br /> Woodland require minimum five(5)nails per shingle. <br /> ➢ Slateline requires minimum six(6)nails per shingle. <br /> Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R21 <br /> Certi�cote of Authorization 1t9503 FL10124-R19 <br /> Revision 21:08/26/2016 <br /> Page 4 of 6 <br />