Laserfiche WebLink
comply with the impact resistant requirement for windborne i Evaluation Reports ! <br /> , , debris regions (ref 1609.1.4 FBC)___ � Created by Independent Third Party: _� <br /> i — -- <br /> 15279.19 019 W4-16 DSIUO-1K479: Can on T <br /> y �Double Skin Insulated PUR(exterior skin 27 ga, min.; interior <br /> �Ridge/Broukstone �skin 27ga. min.) with Overlay Double-Car(92"to 16'0"wide) � <br /> __ � WINDCODEp W4 Garage Door i <br /> ----- - --r — --{ <br /> Limits of Use i Certification Agency Cert�cate � <br /> Approved for use in HVHZ: No i FL15279 R4 C CAC Letter with proof of contrzct znd nreof i <br /> Approved foruse outside HVHZ:Yes i of inspecticn.odf <br /> Impact Resistant: N/A I FL15279 R4 C CAC 1'J4 Listing Intertek.odf <br /> Design Pressure: +25.5 PSF/-25.5 PSF Quality Assurance Contrect Expiration Date <br /> Other:The OPTIONAL glazing availabie for this product � 05/21/2028 I <br /> meets the wind load requirements of the buildfng code but Installation Instructions <br />, DOES NOT meet the impact resistant requirement for FL15779 R4 IT 1�4457-Re��07�pdE � <br /> windborne debris regions.The product without glazing DOES ( Verified By: Intertek Testing Services NA,Inc, i <br /> comply with the impact resistant requirement for windborne Created by Independent Third Party: � <br /> debris regions(ref 1609,1,4 FBC).— �Evaluation Reports � <br /> Created by Independent Third Party: <br /> 15279.20 020 W4-16 PAN-2F153: 73, 1500, �Steel Pan(min. 25 ga.) Double-Car(9'2"to 16'0"wide) <br /> 75, 190, 84A, 94,42,48, 55, 4RST, �WINDCODEp W4 Garage Door <br />, 6RST,��RSF, 6RSF, GDSS, GDSSV, <br /> GR5S, GRSSV,ARSS,ARSSV, EDSS, <br /> EDSS\� <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ: No FI 15279 R4 C CAC Letter with oroof of contract and oroaf <br /> Approved for use outside Hi/HZ:Yes of inspection,odf <br /> Impact Resistant: No FL15279 R4 C CAC VJ4 Listina Intertek.pdf <br />\I Design Pressure: +24 PSF/-24.5 PSF • Quality Assurance Contract Expiration Date <br /> Other:The standard glazing available for this product meets 05/21/2028 <br /> the wind load requirements of the building code but DOES Installation Instructions <br /> NOT meet the impact resistant requirement for windborne F1.15279 R4 II i01711-B-Revl5.pdf <br /> debris regions. Verified By: Intertek Testing Services NA,Inc. <br /> Created by Independent Third Party: <br /> Evaluation Reports <br /> �I Created by Independent Third Party: <br /> I Go to Page '�' � � Page 1/8� � <br /> I <br /> i 0 � <br /> i <br /> IContad Us::2601 Blafr Stone Road.Tallahassee FL 32399 Phone:850-487-1824 <br /> 1 <br /> The State of Florida is an AA/EEO employer.Coovrioht 2007-2013 State of Florida. :: Priva�v Statement::AccessiWlitv Statement::Refund Statement <br /> Under Florida law,emafl addresses are public records.If you do not want your e-mail address released in response to a puhlic-remrds request,do not send electronic <br /> mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Sectlon <br /> 455.275(1),F�orida Statutes,effecUve October 1,2012,Iicensees Ilcensed under Chapter 455,F.S.must provide the Department with an email address if they have <br /> one.The emails provided may be used for official communiration with the licensee.However email addresses are puhlic record.If you do not wish ta supply a <br /> personal address,please provide the Department with an email address which can be made available to the public To determine if you are a Iicensee under Chapter <br /> 455,F.S.,please dick her . <br /> Product ApprovalAccepts: <br /> � "'�? c�CF��, � <br /> Cred+t Card <br /> Safe <br /> � �� ,� <br />