Laserfiche WebLink
EnCon Services, Inc. <br /> Sign Design Calculations <br /> Job Description . PREPARED BY: EnCon Services, Inc. <br /> T Mobile PO Box 3613 <br /> 7335 Gall Blvd. Apollo Beach, FL 33572 <br /> Zephyrhills, Florida P 813-655-3373 <br /> 24"letters on Raceway ` F 813-655-9814 <br /> Design per Florida Building Code, 5th Edition(2014), Section 16 Wind Load, ' FLEB#9394 <br /> ASCE 7-10, Load Case: D+0.6W <br /> Design Specifications Nathan P. Presnell, PE <br /> Risk Category II FLPE 77696 � <br /> Kzt 1 - <br /> Exposure Factor C <br /> Kd 0.85 <br /> Kz 0.98 <br /> ����►«tu�r�u��r� <br /> V 150 (mph) `������`N p Pl� ��9�i,i <br /> Wind P e su el 52.8 (psf) 4, H<60 Feet ``���Q'��C E N S�s�i��' <br /> :��: No 77s9s :� = <br /> - • � <br /> _ . . <br /> = <br /> . <br /> Sign Information � ; = 4 <br /> Height 2.00 (ft) ' :�• �� <br /> i : STATE �F : . <br /> W idth 12.08 (ft) �(}:� � P �: ` <br /> Thickness 1.00 (ft) �i���� •.��R 1�.••'����� <br /> Distance grade to top 30 (ft) ,����Iiss�QNA�,•;,`O��``, <br /> r�iu�tn�u����� <br /> Wind Shear Force 63.33 (Ib) <br /> Weight of Sign 242 (Ib) DATE SIGNED: <br /> Total Shear Force = 249.76 (Ib) 4/27/2017 <br /> Total Tension Force = 765.08 (Ib) <br /> Required Provided <br /> Fastener size(Nominal) 3/8 3/8 � <br /> Minimum number of fasteners 8 8 <br /> Shear Force per fastener Ib 31.2 280 <br /> Tension Force per fastener(Ib) 95.6 352 <br /> Combination Tension and 0.38 <1 O.K. <br /> Shear ratio <br /> THREADED ROD THROUGH WALL IS PREFERRED IN ALL INSTANCES. IF IT IS NOT POSSIBLE TO USE THREADED ROD,SEE CHART BELOW <br /> FOR APPROPRIATE ANCHOR SELECTION:SIZE AND NUMBER REQUIRED ARE NOTED IN THE CHART ABOVE. <br /> WALL STRUCTURE ANCHOR TYPE <br /> WOOD BLOCKING LAG BOLT(3"EMBEDMENT)THROUGH BLOCKING <br /> EIFS OVER 518"PLYWOOD LIBERTY TOGGLE BOLT OR THRU BOLT WITH SLEEVE <br /> HOLLOW CONCRETE BLOCK,BRICK SLEEVE ANCHOR(1-112"EMBEDMEN� <br /> SOLID CONCRETE WEDGE ANCHOR(2-112°EMBEDMEN� <br /> CMU,SOLID CONCRETE,BRICK HILTI HIT ROD WIHY-20 ADHESIVE(3112"EMBEDMENT) <br /> ALL ANCHORS SHALL BE CHOSEN AND PLACED IN ACCORDANCE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS <br /> 4/27/2017 <br /> T Mobile Zephyrhills Gall Blvd 12-0 RW <br />