Metadata
Fields
Template:
Building Department
Company Name
HILL GRAY SEVEN LLC
Building Department - Doc Type
Permit
Permit #
17-18514
Building Department - Name
SUNTRUST
Address
7809 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
139
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Plan Review C103.2 Exterior Lighting Plans,specifications,and/or calculations provide ❑ � ❑ <br /> ` all information with which compliance can be <br /> determined for the exterior lighting and electrical <br /> systems and equipment and document where <br /> exceptions to the standard are claimed. <br /> Information provided should include exterior <br /> lighting power calculations,wattage of bulbs and <br /> ballasts,transformers and control devices. <br /> Wattage C405.62 Exterior Lighting Exterior lighting power is consistent with what is � � ❑ <br /> shown on the approved lighting plans, <br /> demonstrating proposed watts are less than or <br /> equal to allowed watts. <br /> Plan Review C103.2 Interior Lighting Plans,specifications,andlor calculations provide � � � <br /> all information with which compliance can be <br /> determined for the interior lighting and electrical <br /> systems and equipment and document where <br /> exceptions to the standard are claimed. <br /> Information provided should include interior <br /> lighting power calculations,wattage of bulbs and <br /> ballasts,transformers and control devices. <br /> HVAC C403.2.5.1 Mechanical Demand control ventilation provided for spaces � � � <br /> >500 ft2 and>25 people/1000 ft2 occupant <br /> density and served by systems with air side <br /> economizer,auto modulating outside air damper <br /> control,or design airflow>3,000 cfm. <br /> HVAC C403.2.4.3 Mechanical Each zone equipped with setback controls using � � � <br /> automatic time clock or programmable control <br />' system. <br /> Plan Review C103.2 Mechanical Plans,specifications,and/or calculations provide � ❑ � <br /> all information with which compliance can be <br /> determined for the mechanical systems and <br />, equipment and document where exceptions to the <br /> standard are claimed. Load calculations per <br /> acceptable engineering standards and <br /> handbooks. <br /> Plan Review C103.2 Mechanical Plans,specifications,and/or calculations provide � � � <br /> all information with which compliance can be <br /> determined for the service water heating systems <br /> and equipment and document where exceptions <br /> to the standard are claimed. Hot water system <br /> sized per manufacturer's sizing guide. <br /> SYSTEM_SPECIFIC C403.4.5 Mechanical Zone controls can limit simultaneous heating and � � � <br />' cooling and sequence heating and cooling to each <br /> zone. � <br /> SYSTEM_SPECIFIC C403.4.3.1 Mechanical Three-pipe hydronic systems using a common � � � <br /> return for hot and chilled water are not used. <br /> SYSTEM_SPECIFIC C403.4.3.2 Mechanical Two-pipe hydronic systems using a common ❑ � ❑ <br /> distribution system have controls to allow a <br /> deadband>=15 4F,allow operation in one mode <br /> for at least 4 hrs before changeover,and have <br /> rest controls to limit heating and cooling supply <br /> temperature to<=30°F <br /> SYSTEM_SPECIFIC C403.4.3.3.1 Mechanical Hydronic heat pump systems connected to a � � � <br /> common water loop meet heat rejection and heat <br /> addition requirements. <br /> SYSTEM_SPECIFIC C408.2.2.2 Mechanical HVAC hydronic heating and cooling coils have ❑ � � <br /> means to balance and have pressure test <br /> connections. <br /> SYSTEM_SPECIFIC C403.42 Mechanical VAV fan motors>=7.5 hp to be driven by variable � � ❑ <br /> speed drive,have a vane-axial fan with variable <br /> pitch blades,or have controls to limit fan motor <br /> demand. <br /> SYSTEM_SPECIFIC C403.4.2.1 Mechanical VAV fans have static pressure sensors positioned � � � <br /> so setpoint<=1/3 total design pressure. <br /> SYSTEM_SPECIFIC C403.4.2.2 Mechanical Reset static pressure setpoint for DDC controlled � � � <br /> VAV boxes reporting to central controller based on i <br /> the zones requiring the most pressure. i <br /> SYSTEM_SPECIFIC C403.4.5.4 Mechanical Multiple zone HVAC systems have supply air � � � y <br /> temperature reset controls. .I <br /> SYSTEM_SPECIFIC C403.4.3.4 Mechanical Hydronic systems greater than 300,000 Btu/h � � � ' <br /> designed for variable fluid flow i <br /> r <br /> EnergyGauge Summit0 Fla/Com-2014.TAM 2014-1.0 Compliant Software. Effective Date:June 30, 2015 „ <br /> 9/9/2016 Page 9 of 13 � <br /> . <br /> � <br />