My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18519
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18519
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/1/2018 1:07:49 PM
Creation date
5/1/2018 1:07:48 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18519
Building Department - Name
LENNAR HOMES LLC
Address
36078 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2014 <br /> WALLS ' <br /> i <br /> � <br /> �, <br /> Adjacent SPa� Cavity Width Height Sheathing Framing Solar Belo w <br /> _ 1 N=>NW Exterior Concrete Block-Int Insul Main 4.�999 19 3 8 154.0 ft2 0 0.600000 0 , <br /> _ 2 W=>SW Exterior Concrete Block-Int Insul Main 4.0999 65 8 520.0 ft2 0 0.600000 0 <br /> _3 S=>SE Exterior Concrete Block-Int Insul Main 4.0999 40 8 320.0 ft' 0 0.600000 0 I <br /> _4 E=>NE Exterior Concrete Block-Int Insul Main 4.0999 48 8 384.0 ft2 0 0.600000 0 ! <br /> _ 5 N=>NW Garage Frame-Wood Main 11 20 8 160.0 ftZ 0 0.01 0 <br /> _ 6 W=>SW Garage Frame-Wood Main 11 16 8 128.0 ft' 0 0.01 0 <br /> DOORS � <br /> # Ornt Door Type Space Storms U-Value Width Height Area <br /> Ft In Ft In <br /> 1 N=>NW Insulated Main None .2 3 6 8 20 ft� <br /> 2 N=>NW Wood Main None .4 2 8 6 8 17.8 ft2 <br /> WINDOWS <br /> Orientation shown is the entered orientation =>)chan ed to Worst Case. <br /> / Wall Overhang <br /> \/ # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening II <br /> 1 N=>NW 1 Metal Low-E Double Yes 0.56 0.28 23.0 ft2 1 ft 0 in 3 ft 3 in Drapes/blinds None I� <br /> 2 W=>SW 2 Metal Low-E Double Yes 0.54 0.31 32.0 ftz 1 ft 0 in 1 ft 0 in Drapeslblinds None I <br /> 3 S=>SE 3 Metal Low-E Double Yes 0.56 0.32 33.3 ft' 2 ft 0 in 0 ft 8 in Drapes/blinds None I <br /> 4 S=>SE 3 Metal Low-E Double Yes 0.54 0.31 69.0 ft' 1 ft 0 in 1 ft 0 in Drapes/blinds None <br /> GARAGE <br /> # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation �i <br /> 1 416 ftZ 384 ft' 45 ft 8 ft 1 � <br /> INFILTRATION li <br /> # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 I <br /> 1 Wholehouse Proposed ACH(50) .000254 1290.7 70.86 133.25 1906 5 � <br /> HEATING SYSTEM <br /> # System Type Subtype Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump None HSPF:8.7 32.8 kBtu/hr 1 sys#1 <br /> COOLING SYSTEM <br /> # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts <br /> 1 Central Unit S lit SEER:15.2 34.8 kBtu/hr 1044 cfm 0.85 1 s s#1 <br /> P Y <br /> o., <br /> 12/30/2016 8:53 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 � <br />
The URL can be used to link to this page
Your browser does not support the video tag.