Laserfiche WebLink
Manual S Compliance Report Job: 1941sfADS � <br /> Date: 12/30/2016 ! <br /> Entire House By: Dave � <br /> BAYONET PLUMBING COOLING HEATING <br /> ' • • e � <br /> For: Lennar Homes <br /> • s • • • <br /> Design Conditions <br /> Outdoor design DB 91.3°F Sensible gain: 26473 Btuh Entering coil DB. 75.6°F <br /> Outdoor design WB. 77 3°F Latent gain: 4393 Btuh Entering coil WB� 62.8°F <br /> Indoor design DB. 75.0°F Total gain: 30867 Btuh � <br /> Indoor RH 50% Estimated airflow• 1200 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP ' <br /> Manufacturer: Lennox Model: 14HPX-036-230-18+CBX27UH-036-230*++TDR <br /> Actual airflow: 1200 cfm <br /> Sensible capacity: 29580 Btuh 112% of load <br /> Latent capacity: 5220 Btuh 119% of load ' <br /> Total capacity: 34800 Btuh 113% of load SHR: 85% <br /> • • e � <br /> Design Conditions <br /> Outdoor design DB 30.8�F Heat loss: 28865 Btuh Entering coil DB 69.7°F <br /> Indoor design DB: 70.0°F <br /> � Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP � <br /> Manufacturer: Lennox Model: 14HPX-036-230-18+CBX27UH-036-230"++TDR ; <br /> Actual airtlow: 1200 cfm <br /> Output capacity' 32800 Btuh 114% of load Capacity balance: 35 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer n/a Model: n/a+n/a ' <br /> Actual airflow: 1200 cfm <br />, Output capacity: 0 kW 0% of load Temp. rise: 0 °F <br /> The above equipment was selected in accordance with ACCA Manual S. <br /> 201 CrDec-30 10:43:05 II <br /> �n � wrightsoft'� Right-Suite�Universal 2013 13.0.09 RSU05714 Page 1 <br /> �'� H:\LENNAR LOADS\1941 sf ADS 3ton.rup Calc=MJB Front Door faces: N <br /> I <br /> I <br />