Laserfiche WebLink
• FOf�M R405-2014 <br /> WALLS � <br /> Adjacent S a� Cavity Width . Height Sheathing Framing Solar Below ' <br /> P o � <br /> _ 1 N=>NE Exterior Concrete Block-int Insul Main 4.1 15 4 9 4 143.1 ftZ 0 0 0.6 0 ' <br /> _2 S=>SW Exterior Concrete Block-Int Insul Main 4.1 32 0 9 4 298.7 ftZ 0 0 0.6 0 <br /> _ 3 E=>SE Exterior Concrete Block-Int Insul Main 4 1 68 9 4 634.7 ft= 0 0.6 0 <br /> _4 W=>NW Exterior Concrete Block-Int Insul Main 4 1 66 9 4 616.0 ft= 0 0.6 0 <br />, _5 N=>NE Garage Frame-Wood Main 11 28 9 4 261.3 ft� 0.23 0.01 0 <br />, _6 W=>NW Garage Frame-Wood Main 11 9 6 11 4 107.7 ft2 0.23 0.01 0 <br /> i _ 7 N=>NE Exterior Concrete Block-Int insul Main 4.0999 5 4 11 4 60.4 ft' 0 0.600000 0 <br /> _ 8 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 18 11 4 204.0 ft' 0 0.600000 0 i <br /> 9 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 8 9 4 74.7 ft2 0 0.600000 0 <br /> _ DOORS , <br /> # Omt Door Type Space Storms U-Value Width Height Area <br /> Ft In Ft In <br /> 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 <br /> 2 N=>NE Wood Main None .4 2 8 6 S 17.8 ft' <br /> WINDOWS <br /> Orientation shown is the entered orientation =>)chan ed to Worst Case. � <br />� / Wall Overhang <br /> �� # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening <br /> 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 32.0 ftZ 1 fi 0 in 3 ft 0 in Drapes/blinds Exterior 5 <br /> 2 S=>SW 8 Metal Low-E Double Yes 0.58 0.32 72.0 ftZ 8 ft 0 in 0 ft 2 in Drapes/blinds None <br /> 3 E=>SE 3 Metal Low-E Double Yes 0.54 0.31 64.0 ft� 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 <br /> 4 W=>NW 4 Metal Low-E Double Yes 0.54 0.31 16.0 ftZ 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 <br /> 5 E=>SE 9 Metal Low-E Double Yes 0.56 0.32 48.0 ftz 18 ft 0 in 0 ft 2 in Drapes/blinds None , <br /> 6 S=>SW 2 Metal Low-E Double Yes 0.54 0.31 32.0 ft= 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 <br /> 7 S=>SW 2 Metal Low-E Double Yes 0.54 0.31 23.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 <br /> 8 N=>NE 7 Metal Low-E Double Yes 0.56 0.28 6.5 ft� 6 ft 8 in 2 ft 0 in Drapes/blinds Exterior 5 <br /> 9 W=>NW 4 Metal Low-E Double Yes 0.54 0.31 6.7 ft2 1 ft 0 in 1 ft 0 in None None <br /> GARAGE , <br /> # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 589 ft' 589 ftZ 60.8 ft 9.3 ft 1 <br /> INFILTRATION { <br />� # Scope Method SLA CFM 50 ElA EqLA ACH ACH 50 <br /> � <br /> 1 Wholehouse Proposed ACH(50) .000295 2014.2 110.58 207.96 .2216 5 <br /> 1/3/2017 9:20 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 <br />