Laserfiche WebLink
' � � <br /> ' Building Analysis Job: 2600sf <br /> Date: 1/3/2017 <br /> Entire House � By: oa�e , <br /> BAYONET PLUMBING COOLING HEATING ' <br /> ' • - � • <br /> For Lennar Homes � <br /> � - • o • • <br /> Location: Indoor: Heating Cooling <br /> Tampa International AP, FL, US � Indoor temperature(°F) 70 75 <br /> Elevation: 10 ft ' Design TD (°F) 39 16 <br /> Latitude: 28°N Relative humidity (%) 50 50 <br /> Outdoor: Heating Cooling Moisture difference(gr/Ib) 34.7 54.7 <br /> Dry bulb(°F) 31 91 Infiltration: <br /> Daily range(°F) - 14 ( L ) Method Simplified <br /> Wet bulb(°F) - 77 Construction quality Semi-tight <br /> Wind speed(mph) 15.0 7 5 Fireplaces 0 <br /> - . <br /> Component Btuh/ftZ Btuh % of load <br /> Walls 5.6 9884 25.2 <br /> Glazing 30.2 9215 23.5 <br /> Doors 23.5 480 1.2 <br /> Ceilings 1.3 3260 8.3 <br /> Floors 3.2 8238 21.0 <br /> Infiltration 1.9 4052 10.3 <br /> D ucts 4153 10.6 <br /> Piping 0 0 ' � <br /> Humidification 0 0 � <br /> Ventilation 0 0 <br /> Adjustments 0 �- "' <br /> Total 39282 100.0 <br /> � • . <br /> Component Btuh/ftZ Btuh % of load <br /> Walls 2.8 4917 14.3 �'" <br /> Glazing 47 4 14458 42.0 <br /> Doors 18.4 376 1.1 <br /> Ceilings 1.7 4507 13.1 <br /> Floors 0 0 0 � <br /> Infiltration 0.4 843 2.4 � <br /> Ducts 4631 13.5 <br /> Ventilation 0 0 '°'�" <br /> Internal gains 4670 13.6 - <br /> Blower 0 0 � �, <br /> Adjustments 0 ,��,''i��'� � '� <br /> Total 34401 100.0 � ; <br /> Latent Cooling Load=4401 Btuh <br /> Overall U-value= 0.109 Btuh/ftZ-°F <br /> Data entries checked. <br /> �, WI'1 f7tSOft" 2017-Jan-03 09:09:12 <br /> i..... g Right-Suite�Universal 2013 13.0.09 RSU05714 Page 1 <br /> �'C'A H:\LENNAR LOADS�2600 sf ADS drawn 3.5 ton.rup Calc=MJe Front Door faces: E <br />