Laserfiche WebLink
: � <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department af Business and Prafessianal Regulatian - Residential Pertormance Method <br /> Project Name: 2386 sf ADS - Builder Name: Lennar Nomes <br /> street: 36089 Stable Wilk Avenue Perm�t ot�ce: City of Zephyrhills <br /> Cify,State,Zp: ,F!., Permit Number• <br /> Owner Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa <br /> 1 New construction or existing New(From Plans) 9. Wall Types(257Q.5 sqft.) Insulation Area <br /> 2. Single family or mulfiple family Single-family a.Frame-1Naod,E�cteriar R=11.0 9285.74 ft2 <br /> b.Concrete Biock-Int lnsul,EMerior R=4.1 1118.00 ft= <br /> 3. Number of uni#s,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 166.83 ft' <br /> - 4 Number of B�droams 5 d.htA R= ftZ <br /> 5. Is this a worst case? Yes 1 q,Ceiling Types (1272.0 sqft.) Insulation Area � <br /> a.Under Attic(Vented) R=30.0 1120.00 ft <br /> 6. Conditioned floor area above grade{ft2) 2389 b.Knee WaII{Vented) R=30.0 'E52A0 ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ <br /> 11 Ducts R ft2 <br /> 7, Windows{168.0 sqft.} Descsiption Area a.Sup:Attic,Ret:2nd Fioor,AH:2nd Ftaor 6 47Z8 <br /> a. U-Factor Dbl,U=0.54 96.00 ftx <br /> SFiGC: SHGC=4.31 <br /> b. U-Factor dbl,U=0.56 38.68 ft2 12.Cooling systems k8tuthr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 43.5 SEER:15.50 <br /> c. li-Factae. D61,U=0.56 33.33 82 <br /> SHGC: SHGC=0.32 13.Heating systems kBtulhr Efficiency <br /> d. U-Factor� N/A ftz a.Electric Heat Pump 43.5 HSPF:9.OD <br /> SHGC: <br /> Area Weighted Average Overhang Depth. 1.000 ft. <br /> Area Weighted Average SHGC: 0.3Q5 14 Hot water systems <br /> 8, Floor Types (1269.0 sqft.) Insulation Area a.Eiectric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1269.00 ft2 b, Conservation features <br /> b.N1A ft= ft2 None <br /> c.N/A R= �z 15,Credits Pstat <br /> Glass/Floor Area: 0,070 �btal Praposed Modified Loads: 67.32 pASS <br /> Total Baseline Loads: 69.61 <br /> i hereby certify that the plans and specificaYians covered by Review of the plans and ���:ST��, <br /> this calcu}ation are in compliance with fhe Florida Energy specifications covered by this �v�-:.� '_,�,;'�'Q4,�, <br /> Gode. calculation indicates compliance ��rr,�°'' � ='_,�`,•w`.�� <br /> j}j� /� flt1/��t/�j��j with the F(orida Energy Code. ` -`'�',. '�`� � <br /> ll/V4�C/ T1Wi/!V/4 �"�� tFt3{j��ib%;%^;i�,'`��yt��. <br /> PREPARED BY' Before cons#ruction is campieted w ��� '`' � <br /> G1ATE: this building will be inspected for �j "��;�_'�" � <br /> camptsance with Secfion 553.948 �" ���"�- �� �- � <br /> I hereby certify that this building,as designed, is in compliance Flarida Statutes. �t�,, ' ��+�. <br /> with the FlQrida Energy Code. �t?,t?��+yE"'� <br /> OWNER/AGENT: BUILDING QFFIC�L. <br /> DATE: DATE. "z <br /> --Comgliance reyuires certification by the air handler unit manufacturer that the air handler enclosure qualifies as � <br /> certified factory-saated in accortfance with R403.2.2.1. ' <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.7.2. - <br /> - Compliance with a proposed duct ieakage Qn requires a Duct Leakage Test Report confirming dvct leakage ta outdaors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole hause. <br /> 12/30/2016 12:15 PM EnergyGauget�USA-FlaRes2Q14 Section R405.4 1 CompliaM Software Page 1 of 4 <br />