Laserfiche WebLink
t �i <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2575 sf ADS A elv Builder Name: Lennar Homes <br /> street: 36071 Carriage Pine Court Pem,�t o�e�: City of Ze hyrhills <br /> City,State,Zip: ,FL, Permit Number l'��'S� <br /> Owner• Lennar homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2613.8 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1273.30 ft' <br /> b.Concrete Block-Int Insul,Exterior R=4.1 988.00 ft� <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft' <br /> 4 Number of Bedrooms 4 d.N/A R= ft' <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1491.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 1491.00 ft <br /> 6. Conditioned floor area above grade(ftZ) 2584 b.N/A R= ft� <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ft' <br /> 11 Ducts R ft� <br /> 7. Windows(152.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 258.4 <br /> a. U-Factor Dbl,U=0.56 71.00 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 258.4 <br /> SHGC: SHGC=0.28 <br /> b. U-Factor: Dbl,U=0.54 48.25 ftZ 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.31 a.Central Unit 18.0 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.20 <br /> c. U-Factor: Dbl,U=0.56 33.33 ft' <br /> SHGC: SHGC=0.32 � 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ft2 a.Electric Heat Pump 17.5 HSPF:8.50 <br />' SHGC: b.Electric Heat Pump 21.8 HSPF:9.00 <br /> Area Weighted Average Overhang Depth: 1.218 ft. <br /> Area Weighted Average SHGC: 0.298 14 Hot water systems <br />' 8. Floor Types (2585.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft' b. Conservation features <br /> b.Floor Over Other Space R=0.0 1050.50 ft' None <br /> c.other(see details) R= 441.50 ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.059 Total Proposed Modified Loads: 66.73 pASS <br /> Total Baseline Loads: 70.29 <br /> I hereby certify that the plans and specifications covered by Review of the plans and f��:�'T,�q1; <br /> this calculation are in compliance with the Florida Energy specifications covered by this +v�_ '"`_.: '��3 <br /> .,, ;;�_; �• <br /> Code. calculation indicates compliance �'�'si„,g r;'�r :_.;-�,w; �.s� <br /> �ave ��G/. with the Florida Energy Code. <br /> F�'�,�ttata`�'•'",�`;�:~a".�:.��`'��tt�d. <br /> PREPARED BY: � " ��'"�� � <br /> �� Before construction is completed w •- <br /> � . 3�f(�':::� � <br /> DATE: fhis building will be inspected for � �i���' '" � <br /> compliance with Section 553.908 * '�'"� � :� <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. �,;�,� ", ���.• <br /> with the Florida Energy Code. / '�D yyE"� <br /> OWNER/AGENT. BUILDING .FF C A� <br /> DATE: DATE. <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler en osure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confrming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 12/29/2016 12:58 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />