Laserfiche WebLink
, , <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2575 sf ADS A elv Builder Name: Lennar Homes <br /> street: 36071 Carriage Pine Court Permit office: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number• <br /> Owner• Lennar homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2613.8 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1273.30 ft2 <br /> b.Concrete Block-Int Insul,Exterior R=4.1 988.00 ft <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ftz <br /> 4 Number of Bedrooms 4 d.N/A R= ftZ <br /> 10.Ceiling Types (1491.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1491.00 ft2 <br /> 6. Conditioned floor area above grade(ftZ) 2584 b.N/A R= ft2 <br /> Conditioned floor area below grade(ftZ) 0 11 cDucts R R ff2� <br /> 7. Windows(152.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 258.4 <br /> a. U-Factor Dbl,U=0.56 71.00 ftz b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 258.4 <br /> SHGC: SHGC=0.28 <br /> b. U-Factor Dbl,U=0.54 48.25 ft' 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.31 a.Central Unit 18.0 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.20 <br /> c. U-Factor: Dbl,U=0.56 33.33 ftz <br /> SHGC: SHGC=0.32 13.Heating systems � kBtu/hr Efficiency <br /> d. U-Factor� N/A ftZ a.Electric Heat Pump 17.5 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:9.00 <br /> Area Weighted Average Overhang Depth: 1.218 ft. <br /> Area Weighted Average SHGC: 0.298 14•Hot water systems <br /> � a.Electric Cap:40 gallons <br /> S. Floor Types (2585.0 sqft.) Insulation Area EF.0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features <br /> b.Floor Over Other Space R=0.0 1050.50 ft= None <br /> c.other(see details) R= 441.50 ft2 15.Credits Pstat <br /> Glass/Floor Area. 0.059 Total Proposed Modified Loads: 66.73 pASS <br /> Total Baseline Loads. 70.29 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��¢'G�S�".Q�•� ` <br /> this calculation are in compliance with the Florida Energy specifications covered by this '�v�,�,� ,^4;. 0,�,,` <br /> Code. calculation indicates compliance ���i�, '' °;'"j'�` �t,. <br /> �a�e �/J�G/, with the Florida Energy Code. � t+rafr-�'."�%•.;•:=�'°�;':r',�,� � . <br /> ..: �;.. <br /> PREPARED BY. ��� YG Before construction is completed �. ;;� � <br /> F4 , � 1�;-_ .-. <br /> DATE. this building will be inspected for �,ry�,,,"�,,�.� � <br /> compliance with Section 553.908 ,, °o <br /> Florida Statutes. �C <br /> I hereby certify that this building, as designed, is in compliance ` ,��.s <br /> with the Florida Energy Code. ����� <br /> OWNER/AGENT: BUILDING OF C L,� <br /> DATE: DATE: � <br /> - - Compliance requires certification by the air handler unit manufacturer that the air handler encl re qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 12/29/2016 12:58 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />