Laserfiche WebLink
> <br /> r i <br /> .,, � <br /> . Manual S Compliance Report Job: 2575sfADS Aelevation <br /> Date: 12/30/2016 <br /> upper floor By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> ' • - s s <br /> For• Lennar Homes <br /> • s • e • <br /> Design Conditions <br /> Outdoor design DB 91.3°F Sensible gain: 19271 Btuh Entering coil DB: 75.6°F I <br /> Outdoor design WB. 77.3°F Latent gain: 2643 Btuh Entering coil WB: 62.8°F , <br /> Indoor design DB: 75.0°F Total gain: 21913 Btuh <br /> Indoor RH: 50% Estimated airtlow: 800 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-024-230-18+CBX27UH-024230*++TDR <br /> Actual airflow: 800 cfm <br /> Sensible capacity: 21420 Btuh 111% of load <br /> Latent capacity: 3780 Btuh 143% of load <br /> Total capacity� 25200 Btuh 115% of load SHR: 85% <br /> . . • <br /> Design Conditions <br /> Outdoor design DB. 30.8°F Heat loss: 12846 Btuh Entering coil DB. 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Pertormance Data atActual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-024230-18+CBX27UH-024230*++TDR <br /> Actual airflow: 800 cfm <br /> Output capacity: 21800 Btuh 170% of load Capacity balance: 25 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: � <br /> Actual airflow� 800 cfm <br /> Output capacity: 3.5 kW 92% of load Temp. rise: 50 °F <br /> The above equipment was selected in accordance with ACCA Manual S. <br /> 201CrDec-30 07•49:08 � <br /> � wrightsoftp Right-Suite�l LJniversal 2013 13.0.09 RSU05714 Pa e Z <br /> 9 <br /> �'� H:\LENNAR LOADS\2575 sf ADS-A elv 1.S2ton.rup Calc=MJ8 Front Door faces: S <br />