Laserfiche WebLink
R R W Buildirzg Consultants, Inc. <br /> uj Consulting nnd Engineering 5ervices for the Building Industry <br /> B P.O.Box 230 Vnlrico,6L 33595 Phone S 13.659.9197 <br /> CFlorida Board of Professiona]Engineers Cectificate of AuUiorization No.9813 <br /> � � � , ,�� ' i� � l <br /> 1 i ! r <br />� <br /> I • <br /> Product Sub Category Manufacturer Product Name <br /> Cafegory • � <br /> Associated Materials Inc. Model 3001/3B01/3A01/3AB1"ST" <br /> Window Double Hung 3773 State Road Extruded Vinyi ,I <br /> Cuyahoga Falls,OH 44223 Doubie Nung"ReplacemenY'Window <br /> Phone 330.922.2108 "Non-Impact" I <br /> Scope: Product Evaluafion report issued by R W Building Consultants,Inc.8�Lyndon F.Schmidt,P.E.(System ID#1998)for ii <br /> Associated Materials Inc.,based on Rule Chapter No.61 G20-3,Method 1 D of the State of Florida Product Approval,Dept. <br /> of Business&Professional Regulation. <br />� RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor wiil acquire financial interest in the company <br /> manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. <br /> LimitaSons: , <br /> 1. This product has been evaluated and is in compliance with the 5th Edition(20'14)Florida Building Code structural requirements ' <br /> exciuding the"High Velocity.Hurricane Zone". <br /> 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing <br /> or stucco. <br />� 3. When used in areas requiring wind borne debris protection,this product is required to be protected with an impact resistant covering that <br /> complies with Section 1609.1.2 of the Florida Building Code. <br />� 4. For 2X stud construction,anchoring of the assemblies shall be as shown for 2X buck masonry construction. <br /> 5. Site condifions that deviate from the details of drawing FL-11720.13 require furthe�engineering analysis by a licensed engineer or <br /> registered architect. <br /> 6. See drawing FL-11720.13 for size and design pressure limitations. <br /> Supporting Documents: <br /> j 1. Test Report No. Test Standard Testinq Laboratorv Siqned bv <br /> ATI D2492.01-501-47 AAMAlWDMA/10111.S.2/A440-OS Architectural Testing,Inc. Lynn George <br /> ATI D3073.01-109-47 AAMA/WDMA/101/I.S.2/A440-08 Architectural Testing,Inc. Michael D.5tremmel,P.E. , - <br /> ATI D4961.06-509-47 AAMA/WDMA/101/I.S.2lA440-08 Architectural Testing,Inc. Lynn George � <br /> ATI D3479.06-501-47 AAMAIWDMA/101/I.S.2/A440-08 Architectural Testing,Inc. Lynn George <br /> MT 13-0128-03-B AAMAIWDMA/10111.S.2/A440-08 MT Group Wayne Breighner <br /> 2. Drawinq No. Prepared bv Siqned&Sealed bv � <br /> No.FL-11720.13 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> 3. Calculations Prepared bv Siqned&Sealed bv <br /> ProductAnchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> BuckAnchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> 0Qe�99�998 B9y'�+p�B <br /> 4. Qualitv Assurance oo`��� �•.c.'�•C��'�'O�✓s,, <br /> Certificate of Participation issued by Architectural Testing,Inc.,certifying that mm° �;�•'�G��S� • so� <br /> �o ; �' F �''• �. <br /> Associated Materials Inc.is manufacturing products within a quality b ; Pvo 4'3409 � <br /> assurance program that complies With ISOIIEC 17020 and Guide 53. 4=}; •;�r � <br /> o .. <br /> � a � <br /> m , x � <br /> a. • : <br /> "�p . o <br /> a�' STAiE OF " <br /> : <br /> oa�, �� o�:`�ooe. <br /> osacr''�• �R� � ,� <br /> opB tss ' r� �� Lyndon F.Schmidt,P.E. <br /> BOAO,�OMA��e0�� FL PE No.43409 <br /> 7/26/2016 <br /> Sheet 1 of 1 <br />