Laserfiche WebLink
R. � R �V Build�ng �ansultants, Tnc. <br /> � Consulting and Engineering Services for tlze Building Industry <br /> G P.O.Box 230 Vatrico,FL 33595 Phone 813.659.9197 � <br /> Florida Bo9rd ofProfessional Engineers Certificate af Authorizatiqn No.9813 <br /> � t t �/ ' rt t l � <br /> ! <br /> Product $��������� �lanufacturer Product Name <br /> � Category <br /> AssociaYed Materials,Inc, 3100 5tructural Mullion <br /> Windou�t Mulftons 37T3 Stafe Road <br /> Cuyahoga�alis,OH 44223 <br /> Ph4ne 330.922.b354 <br /> Scope: This is a Eroduct Evaluation repo�t issued by R W Building Consul#ants,lnc.and Lyndon F,Schmidt,P.E.(System ID# <br /> '1998}farAssocia#ed Meferials,Inc:based ciri Ru1e Chapfer No.61 G20-3,Method 2B of the S#afe of Florida Product <br /> Approval,Department af Business&Professianal Regulation. <br /> RW Bui�cling Consuitar�fs and Lyndon F.Schmidt,P.E.do nat have norwiil acquire financial interest in fhe company <br /> manuf�cturing nr distribUting the product or I�any other entity involve�i in the appraval process of the praduct named <br /> herein. <br /> Limitatfonsr <br /> 1. 1`his product has been eva[uafed anr!is•in compSianee with the 5th Edifian(201.4}Florida Buitding Gode{F8C}exctuding#he"Eligh <br /> Velocity Hurricane Zone"and conforms ta the requiremenfs of FBC Chapter 17. <br /> 2. Wood bucks 6y others,must be anchored praper{y to transfer iaads fa the structure and 6e reviawed by the buiiding officia3. <br /> 3. Mullion anchor embedment to base material shall be beyand wall dressing or stucco. <br /> 4. When used in areas requir.ing wind borne debris protection,.this product does not require protection with an impact resistant covering <br /> when used in Wind Zones 1,2 and 3 as defined by ASTM E 1996;in Wind Zone 4 as defined by ASTM E 1996,this produc#must be <br /> protected with an impact resistant cavering complying with Secfion 1609.1.2 of the FBG. <br /> 5. Separate product approvals for each glazing product used with these mu!lions must be submitted along with this mullion praduct <br /> approval. <br /> 6� Anchoring of eaGh�lazing producfi to tlie mullion shaU be as shown in each indlvidua!glazing product approval. <br /> 7, Any conditians not covered in this evaluation are subject to separate engineering evaluation. <br /> 8. Mullion design pressure rafing,see ioad rating fable sheets 2 and 3 of drawing FL-12478.1.. <br /> 9. The design pressure sating of the assem�ily shall be the lesser of the load capacity of the mullion as determined using this approval ar <br /> the design pressure rafing of fhe ind3vidual glazing products used. <br /> 90.Bounding box dimensions fo�geometric shapes must be equal to or less than the rectangular dimensians shown herein. <br /> 11.See drawing FL-12078.1 for size.and design pressure limitations. <br /> Supparttng,Doct�ments: <br /> {�£;�',�ryE��:M��;i�,.�� <br /> 1. Drawina No. Prepared bv :':��",`' �=°�. '.�,;3= Siclned&Sealed bV <br /> ��. <br /> No.FL-�i2078.1 RW�uilding Consultanfs,inc.{CA#9813} ��.�`' .'° -..Lyndan F.&chmidt,P.�. i <br /> :.; - - • •.. <br /> :� • ._.. <br /> 2. Calculatians Prepared bY " ; ,.� - ' Siqned&Sealed bv <br /> ��: <br /> MullionlAnchoring RW Building Consultants,Inc.�CA#9813) - �, ., � . . � . . ;`=!:'Y�dan F.Schmidt,P.�. - - <br /> 3. Qualitv Assurarrce � : � <br /> Certificate o#Pa�icipation issued by Architecfural Testing,Jnc.,certifying = �, . ,. . . ' . ,�,:+�"`� , <br /> , that Associated M�terials,Inc.is manufacturing products within a qualiry ; " � , �, ��` <br /> assurance pragram tha#complies with!SOlIEC 17020 and Guide 53. ���`.. . � - . , , � <br /> •� , Lyndon F.Schmidt,P.E. <br /> • _ �� FL PE Na.434tl9 <br /> ..'" 3/4/2015 <br /> Sheet 1 of'S <br />