Mounting Notes <br /> bCaution: The mounting options figures 5. Use care and proper techniques to <br /> show the maximum number of field wires position the field wires in the back box , <br /> (conductors) that can enter the back box so that they use m�inimum space and ', <br /> used with each mounting option. produce minimum stress on the I <br /> If these limits are exceeded, there may be product.This is especially important <br /> insufficient space in the back box to for stiff, heavy gauge wires and wires <br /> accommodate the field wires with thick insulation or sheathing. <br /> and stresses from the wires could damage 6. Do not pass additional wires (used for <br /> the product. other than the appliance) through the <br /> Although the limits shown for each back box"unless the back box is of a <br /> mounting option comply with the National sufficient size to permit additional <br /> Electrical code (NEC), Siemens wiring as described in NEC 314.16 (B)". <br /> recommends use of the largest back box Such additional wires could result in <br /> option and the use of approved field wires insufficient wiring space for the <br />� whenever possible to provide additional appliance. <br /> wiring room for easy installation and Note: Due to continuous development of our <br /> minimum stress on the product from products, specifications and offerings are subject <br /> wiring. , to change without notice, in accordance with <br /> eCaution: Check that the installed product Siemens Industry, Inc. standard terms and <br /> will have sufficient clearance and wiring conditions. <br /> room prior to installing back-boxes and <br /> conduit, especially if sheathed multi- Back Box Mounting <br /> conductor cable or 314" conduit fittings are Siemens Wall-Mounted, Horizontal Strobe <br /> USed. Appliances NFPA-72 (2007) <br /> 1 Mounting hardware for each 7.5.4.1 * —Wall-mounted appliances shall be <br /> mounting option is supplied. mounted such that the entire lens is not less <br /> 2. Conduit entrances to the back box than 2030 mm (80 in.) and not greater than <br /> should be selected to provide 2440 mm (96 in.) above the finished floor or at <br /> sufficient wiring clearance for the the mounting height specified using the <br /> installed product. performance-based alternative 7.5.4.5 <br /> 3 When extension rings are required, 7.5.4.2—Where low ceiling heights do not <br /> conduit should enter through the permit mounting at a minimum of 2030 mm <br /> back box, not the extension ring. (80 in.), visible appliances shall be mounted <br /> Use Steel City #53151 (1-112" deep) within 150 mm (6 in.) of the ceiling. The room <br /> or #53171 (2-118"deep) extension size covered by a strobe of a given value shall <br /> rings (as noted in the mounting be reduced by twice the difference between <br /> - options) or equal with the same cut- the minimum mounting height of 2030 mm <br /> out area. (80 in.) and the actual, lower mounting height. <br /> 4. When terminating field wires, do not <br /> use more lead length than required. <br /> Excess lead length could result in <br /> insufficient wiring space for the <br /> appliance. <br /> SIEMENS Industry, Inc. <br /> Building Technologies Division — <br />