Laserfiche WebLink
S <br /> , �L <br /> FbRM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDIIVG CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br />' Project Name: Triplex Driftwood townhomes Builder Name: <br />� Street: Permit Office: Hillsborough <br /> City,State,Zip: Zephyrhills,FL, Permit Number: j�93 <br /> Owner: Driftwood Town Homes Jurisdiction: (v j l�Da <br /> Design Location: FL,Tampa County:: Hillsborough(Florida Climate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(3276.0 sqft.) Insulation Area <br /> 2. Single family or muftiple family Multi-family a.Concrete Block-Int Insul,Exterior R=5.0 2394.00 ft= <br /> b.Frame-Wood,Adjacent R=11.0 882.00 ft <br /> 3. Number of units,if multiple family 1 c.N/A R= ft� <br /> 4. Number of Bedrooms 6 d.N/A R- ft= <br /> 10.Ceiling Types (4152.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 4152.00 ft2 <br /> 6. Conditioned floor area above grade(ft�) 4152 b.N/A R= ft' <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ft' <br /> 11.Ducts R ft= <br /> 7 Windows(274.3 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 80 <br /> a. U-Factor: Dbl,U=0.30 274.31 ftZ <br />� SHGC: SHGC=0.26 <br /> b. U-Factor: N/A ft= 12.Cooling systems kBtu/hr Efficiency <br /> a.Central Unit 67.8 SEER:14.00 <br /> SHGC: <br /> c. U-Factor: N/A ft' � <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N!A ft= a.Electric Strip Heat 51.2 COP:1.00 � <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.000 ft. <br /> Area Weighted Average SHGC: 0.260 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (4152.0 sqft.) Insulation Area EF:0.920 <br /> a.Slab-On-Grade Edge Insulation R=0.0 4152.00 ft= b. Conservation features <br /> b.NlA R= ft2 None <br /> c.N/A R= ft' 15.Credits Pstat <br /> j Total Proposed Moclified Loads: 104.38 <br /> Glass/Floor Area: � 66 Total Baseline Loads: 108.67 PASS <br /> I hereby certify that the� la s and specifications covered by Review of the plans and ��TIIE$T,q�,� <br /> this calculation are in m��i�nce with the Florida Energy specifications covered by this ti ,,, "� _: . 0,�, <br /> Code. -, ` � calculation indicates compliance y'��i.,��' � ,;=s s',.����',�. <br /> ` !+. 11h�r•'* "''�:'°:>qd"•c';�°�.�''��� Q� <br /> with the Florida Energy Code. ,. <br /> � Before construction is completed � <br /> PREPARED BY: � __�j,!.... __. � C7 <br /> .1 this building will be inspected for � � a <br /> DATE: _ �'s(�` � <br /> compliance with Section 553.908 * � <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. 1 ���, <br /> with the Florida Ener C de. L�'�/� �D WBT� <br /> BUILDING O FICIA :� � <br /> OWNER/AGEN : _� <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> Gau e0 USA-FlaRes2014 Section R405.4 1 Compliant Sofiware Page 1 of 4 , � <br /> 5/1 2/2 0 1 7 1:3 7 P M E n e r g y g <br /> i <br />