My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18612
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18612
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2018 6:41:58 AM
Creation date
5/2/2018 6:41:57 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18612
Building Department - Name
LENNAR HOMES LLC
Address
6539 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
z_ � ` I <br /> I <br /> FORM R405-2014 j <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION � <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2600 sf ADS Builder Name: LENNAR HOMES <br /> street: 6539 Paden Wheel Street Pem,it o�ice: Ci�y o�Zephyrhills � <br /> City,State,Zip: ,FL, Permit Number �F� � <br /> Owner• LENNAR HOMES Jurisdiction: C1�(Q(� � <br /> Design Location: FL,Tampa � <br /> � I <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2400.6 sqft.) Insulation Area ' <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 2031.60 ft2 � <br /> b.Frame-Wood,Adjacent R=11.0 369.00 ftZ <br /> 3. Number of units,if multiple family 1 c.N/A R- ft= � <br /> 4 Number of Bedrooms 4 d.N/A R= ft' <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2600.0 sqft.) Insulation Area 2 � <br /> a.Under Attic(Vented) R=3�.0 2193.00 ft <br /> 6. Conditioned floor area above grade(ft2) 2599 b.Cathedral/Single Assembly(Vented) R=30.0 407.00 ft� <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11 Ducts R ft' <br /> 7. Windows(300.2 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 645 <br /> a. U-Factor Dbl,U=0.54 141.68 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=�.58 72.00 ft' 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 43.5 SEER:15.50 <br /> c. U-Factor Dbl,U=0.56 48.00 ft' �I <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• other(see details) 38.50 ft� a.Electric Heat Pump 43.5 HSPF:9.00 <br /> SHGC: other(see details) <br /> Area Weighted Average Overhang Depth. 5.520 ft. <br /> Area Weighted Average SHGC: 0.310 14 Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. FloorTypes (2599.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2599.00 ft2 b. Conservation features I <br /> b.N/A R= ft' None i <br /> c.N/A R= ftZ 15.Credits Pstat ' <br /> Total Proposed Modified Loads. 75.53 � <br /> Glass/Floor Area. 0.115 Total Baseline Loads: 78.49 PASS '' <br /> � <br /> I hereby certify that the plans and specifications covered by Review of the plans and ,��'�s�"��.�, . I <br /> this calculation are in compliance with the Florida Energy specifications covered by this � '4� ,��� �4�0�,,. <br /> Code. calculation indicates compliance r,s�n„�` �s=>�a� � <br /> F, »r,ir�,;;;,:-':,`,��'�.`titi�O. <br /> with the Florida Energy Code. � ` "�"'��� <br /> .. � , <br /> PREPARED BY: �ave ���� Before construction is completed �� �:;, ' •' � <br /> DATE: this building will be inspected for Lry_"`�'�`" � ' �' _ � <br /> compliance with Section 553.908 � `� � � <br /> I hereby certify that this building,as designed, is in compliance <br /> Florida Statutes. �',�,; �� ��� � <br /> with the Florida Energy Code. ����� <br /> OWNER/AGENT: BUILDING FFICIAL. I <br /> DATE: DATE. ' � <br /> � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as � <br /> certified factory-sealed in accordance with R403.2.2.1. i <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. � <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. � <br /> 1/3/2017 9:20 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.