My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18614
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18614
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2018 6:44:03 AM
Creation date
5/2/2018 6:44:01 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18614
Building Department - Name
LENNAR HOMES LLC
Address
36077 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� l. <br /> Manual S Compliance Report Job: 1791 sfADS <br /> Date: 3l30/2017 <br /> En tire Ho use By: Dave <br /> BAYONET PLUMBING COOLING HEATING � <br /> . ; <br /> i <br /> i <br /> • a • o <br /> For Lennar Homes � <br /> • . . • . <br /> Design Conditions _ <br /> Outdoor design DB. 91.3°F Sensible gain: 22347 Btuh Entering coil DB 75.7°F <br /> Outdoor design WB� 77.3°F Latent gain: 3398 Btuh Entering coil WB� 62.8°F <br /> Indoor design DB 75.0°F Total gain: 25744 Btuh <br /> Indoor RH. 50% Estimated airflow� 1000 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Nlanufacturer: Lennox Model: 14HPX-030-230-18+CBX27UH-030-230'++TDR <br /> Actual airflow: 1000 cfm <br /> Sensible capacity� 24670 Btuh 110% of load � <br /> Latent capacity: 4360 Btuh 128% of load <br /> Total capacity: 29030 Btuh 113% of load SHR. 85% <br /> • . • <br /> Design Conditions <br /> Outdoor design DB 30.8°F Heat loss. 25127 Btuh Entering coil DB. 69.6°F <br /> Indoor design DB: 70.0°F , <br /> Manufacturer's Performance Data atActual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer� Lennox Model: 14HPX-030-230-18+CBX27UFi-030-230'`++TDR <br /> Actual airflow� 1000 cfm <br /> Output capacity: 26400 Btuh 105% of load Capacity balance: 37 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip , <br /> Manufacturer n/a Model: n/a+nla <br /> Actual airflow: 1000 cfm " � <br /> Output capacity: 0 kW 0% of load Temp. rise: 0 °F , <br /> The above equipment was selected in accordance with ACCA Manual S. <br /> .� wri htsoft` 2017-Marv30 08:23:27 <br /> �� � 9 Right-Suite�Universal 2013 13.0.09 RSU�5714 Page 1 <br /> �� H:\LENNAR LOADS\1791 sf ADS drawn 2.Ston.rup Calc=MJB Fronl Door faces: S <br />
The URL can be used to link to this page
Your browser does not support the video tag.