My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18615
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18615
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2018 6:45:09 AM
Creation date
5/2/2018 6:45:07 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18615
Building Department - Name
LENNAR HOMES LLC
Address
6551 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� 7 . <br /> FORM R405-2014 <br /> r FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> � <br /> Project Name. 3711 SF Builder Name: LENNAR HOMES I <br /> street: 6551 Paden Wheel Street Permit o�ice: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number <br /> Owner• LENNAR HOMES Jurisdiction: 6110�0 � <br /> Design Location: FL,Tampa <br /> 1. New construction or existing New(From Plans) 9. Wall Types(3424.9 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1738.70 ft' <br /> b.Concrete Block-Int Insul,Exterior R=4 1 1487.10 ft' <br />' 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 199.11 ft' <br /> 4 Number of Bedrooms 4 d.N/A R= ft' <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2130.0 sqft.) Insulation Area � <br /> a.Under Attic(Vented) R=30.0 1998.00 ft <br />� 6. Conditioned floor area above grade(ftz) 3711 b.Knee Wall(Vented) R=30.0 132.00 ft� <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ft� <br /> 11 Ducts R ft= <br /> 7. Windows(358.9 sqft.) Description Area a.Sup: 1st Floor,Ret:1st Floor,AH:1st Floor 6 525 <br /> a. U-Factor Dbl,U=0.56 133.00.ftz b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 430 <br /> SHGC: SHGC=0.28 <br /> b. U-Factor Dbl,U=0.54 119.25 ft= 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.31 a.Central Unit 25.2 SEER:16.20 <br /> b.Central Unit 25.2 SEER:16.20 <br /> c. U-Factor Dbl,U=0.56 106.67 ftZ <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr E�ciency <br /> d. U-Factor• N/A ft2 a.Electric Heat Pump 21.8 HSPF:9.00 i <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:9.00 <br /> Area Weighted Average Overhang Depth: 2.938 ft. <br /> Area Weighted Average SHGC- 0.302 14 Hot water systems i <br /> S. Floor Types (1986.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF.0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1713.00 ftz b. Conservation features <br /> b.Floor over Garage R=11.0 273.00 ft' None <br /> c.N/A R= ft2 15.Credits Pstat � <br /> Glass/Floor Area: 0.097 Total Proposed Modified Loads: 97.04 � A C C <br /> Total Baseline Loads: 98.86 �1���� <br /> I�i <br /> I hereby certify that the plans and specifications covered by Review of the plans and �'�:�7'<q?. I <br /> this calculation are in compliance with the Florida Energy specifications covered by this �•� ,� �_.��CY,�,�, 'i <br /> Code. calculation indicates compliance �'��,,,°' '_'-�=,:`�.. +fi. <br /> �. ::__,.� ��'c'` <br /> /, with the Florida Energy Code. � rr�ar�'.'��••.r;:�a�,:,�,'��,,,,ti O <br /> PREPARED BY' �ave ����Yc Before construction is completed w r '`" � ; <br /> � . .�"��,�. ..... _�; <br /> DATE: this building will be inspected for try: , <br /> i� .• <br /> compliance with Section 553.908 �. �'� � �, , <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. ��,C ._ � y��� <br /> with the Florida Energy Code. dD�yE`� , <br /> i <br /> OWNER/AGENT. BUILDING OFFICIAL: <br /> DATE: DATE. <br /> i <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as ! <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage ' <br /> test report in accordance with R402.4.1.2. <br /> 12/30/2016 2:05 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.