Laserfiche WebLink
� , . . <br /> Manual S Compliance Report Job: 3711 sfADS <br /> Date: 12/30/2016 <br /> upper floor By: Dave <br /> Bayonet Plumbing Heating and Cooling <br /> ' s - • o <br /> For: Lennar Homes <br /> e o • • • <br /> Design Conditions <br /> Outdoor design DB� 91.3°F Sensible gain: 20703 Btuh Entering coil DB 75.7°F <br /> Outdoor design WB: 77.3°F Latent gain: 1859 Btuh Entering coil WB� 62.9°F <br /> Indoor design DB• 75.0°F Total gain: 22563 Btuh <br /> Indoor RH 50% Estimated airflow: 800 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br />, Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-024230-18+CBX27UH-024-230*++TDR <br /> Actual airtlow� 800 cfm <br /> Sensible capacity: 21420 Btuh 103% of load � <br /> Latent capacity: 3780 Btuh 203% of load , <br /> Total capacity� 25200 Btuh 112% of load SHR. 85% <br /> • . . , <br /> Design Conditions <br /> Outdoor design DB. 30.8°F Heat loss: 18942 Btuh Entering coil DB. 69.6°F � <br /> Indoor design DB� 70.0°F ; <br /> i <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer Lennox Model: 14HPX-024-230-18+CBX27UH-024230'`++TDR <br /> Actual airflow: 800 cfm � <br /> Output capacity: 21800 Btuh 115% of load Capacity balance: 35 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F ' <br /> Backup equipment type: Elec strip <br /> Manufacturer Model: <br /> Actual airflow: 800 cfm � <br /> Output capacity: 6.0 kW 108% of load Temp. rise: 50 °F <br /> The above equipment was selected in accordance with ACCA Manual S. <br /> ,�, wri htsoft� 2016-Dec-3013:53:05 <br /> � � 9 Right-Suite�Universal 2013 13.0.09 RSU05714 Page 2 <br /> �'� H:\LENNAR LOADS\3711 sf ADS drawn 2-2tons.rup Calc=MJ8 Front Door faces: N <br />