� . Flarida Building Code Online - Page 2 of 7
<br /> �
<br /> Date Submitted 03/19/2015
<br /> Date Validated 06/12/2015
<br /> Date Pending FBC Approval
<br /> Date Approved 06/21/2015
<br /> Summary of Products
<br /> Go to Page 7� � �1 � Page 7/8 i� �
<br /> FL# Model,Number or Name Description ,
<br /> 15279.121 121 W6-18 PAN-2F443:G4S,GS4, Galiery/Artistry/Expressions: Steel Pan(min.24 ga.)16'4"
<br /> GD4S,GR4S,G4SV,GS4V,GD4SV, to 18'2"wide WINDCODEp W6 Garage Door
<br /> GR4SV,E4S,ED4S,E4SV,ED4SV,
<br /> SS4,AR4S,SS4V,AR45V
<br /> Limits of Use Certification Agency Certificate
<br /> Approved for use in HVHZ: No FL15279 R4 C CAC Letter with oroof of contract and oroof
<br /> Approved for use outside HVHZ:Yes of insoection.odf
<br /> Impact Resistant:Yes FL15279 R4 C CAC W6 Listinq Intertek,odf
<br /> Design Pressure:+37 PSF/-39 PSF Quality Assurance Contract Expiration Date
<br /> Other:Solid doors(no standard glazing)are impact- OS/21/2028
<br /> resistant(large missile impact). Installation Instructions �
<br /> FL15279 R4 II 103406-A-Rev06.odf
<br /> Verified By: Intertek Testing Services NA Inc.-
<br /> EfL/Warnock Hersey
<br /> Created by Independent Third Party:
<br /> Evaluation Reports
<br /> Created by IndependentThird Party:
<br /> - 15279.122 122 W6-18 PAN-2F443: G4S,GS4, Gallery/Artistry/Expressions: Steel Pan(min.24 ga.)16'4"
<br /> GD4S,GR4S,G4SV,GS4V,GD4SV, to 18'2"wide WINDCODEp W6 Garage Door
<br /> GR4SV,E4S,ED4S,E4SV,ED4SV,
<br /> SS4,AR4S,SS4V,AR4SV
<br /> Limits of Use Certification Agency Certificate -
<br /> Approved for use in HVHZ:No FL15279 R4 C CAC Letter with oroof of contract and oroof
<br /> Approved for use outside HVHZ:Yes of insoection.odf
<br /> Impact Resistant:No FL15279 R4 C CAC W6 Listina Intertek.odf
<br /> Design Pressure:+37 PSF/-39 PSF Quality Assurance Contract Expiration Date
<br /> Other:The standard glazing avallable for this product OS/21/20Z8
<br /> meets the wind load requirements of the building code but Installation Instructions
<br /> DOES NOT meet the impact resistant requirement for FL15279 R4 II 103406-B-Rev06.odf
<br /> windborne debris reglons. Verified By:Intertek Testing Services NA Inc.-
<br /> ETL/Warnock Hersey
<br /> Created by Independent Third Party:
<br /> Evaluation Reports
<br /> Created by Independent Third Party:
<br /> 15279.123 123 W4-09 DSIE-1F171:4300, 2"Double-skin Insulated EPS(exterior skin 27 ga.min.;
<br /> 4301,4310,4400,4401,HDG, interior skin 27 ga.min.)Single-Car(up to 9'0"wide)
<br /> HDGL,HDGF,66,66G,67,67G, WINDCODEp W4 Garage Door
<br /> 68,SP200,SF200,SE200,6200, �
<br /> 6201,6203
<br /> Limits of Use Certification Agency Certificate
<br /> Approved for use in HVHZ:No FL15279 R4 C CAC Letter with oroof of contract and oroof
<br /> Approved for use outside HVHZ:Yes of insoection.odf
<br /> Impact Resistant:Yes FL15279 R4 C CAC W4 Llstinq Intertek.odf ,
<br /> Design Pressure:+28 PSF/-29 PSF Quality Assurance Contract Expiration Date
<br /> Other:Solid doors(no glazing)or doors with optlonal O5/21/2028 �
<br /> impact-resistant glazing are Impact-resistant(large missile Installation Instructions �
<br /> impact). FL15279 R4 II 101652-A-Revll.odf
<br /> Verified By: Intertek Testing Services NA Inc.- �
<br /> ETL/Warnock Hersey
<br /> Created by Independent Third Party: �
<br /> Evaluation Reports i
<br /> Created by Iridependent Third Party: '
<br /> I
<br /> 15Z79.124 124 W4-16 DSIE-1F171:4300, 2"Double-skin Insulated EPS(exterior skin 27 ga.min.;
<br /> 4301,4310,4400,4401,HDG, lnterior skin 27 ga.min.)Double-Car(9'2"to 16'0"wide) i
<br /> HDGL,HDGF,66,66G,67,67G, WINDCODEp W4 Garege Door
<br /> 68,SP200,SF200,SE200,6200,
<br /> 6201,6203 �
<br /> Limits of Use Certification Agency Certificate
<br /> Approved for use in HVHZ:No FL15279 R4 C CAC Letter with proof of contract and�roof
<br /> Approved for use outside HVHZ:Yes of insoection.odf
<br /> Impact Resistant:Yes FL15279 R4 C CAC W4 Listinq Intertek.�df
<br /> Design Pressure:+25.5 PSF/-25.5 PSF Quality Assurance Contract Expiration Date
<br /> Other:Solid doors(no glazing)or doors with optfonal OS/21/2028
<br /> tmpact-resistant glazing are impact-resistant(large missile Installation Instructions
<br /> impact). FL15279 R4 II 101481-A-Revl3.odf
<br /> Verified By: Intertek Testing Services NA Inc.-
<br /> http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv3yVVKJZ 1 QR... 4/8/2016
<br />
|