Laserfiche WebLink
� � � • i <br /> I � c <br /> � � o <br /> � � � � � � � <br /> „� �� <br /> MODEL�O'I1A IVIODEL�O��/�SG DIMENSIONS <br /> I�B�I Orifice Size Available:3/a",'/is",�/z",��/sz", ELO(5/a") <br /> I�e�I f Model A B C D <br /> � ^ o V €lil 3011A 3�/6�� 4»/6�� ���8�� 4��8�� <br /> 1 � ��� 1 p5 mm) (118 mm) (200 mm) (124 mm) <br /> � 3011ASG 3�/6�� 4»/s" 9�/is" 6�/a" <br /> � � � p6 mm) (1;8 mm) (237 mm) (159 mm) <br /> � — 0 3011BV 3/is 4 /s _ _ <br /> D p5 mm) (11 B mm) <br /> � � � 3011SG 3�/is" 4»/s" 6�/is" 3�/a" <br /> m � p5 mm) (178 mm) (157 mm) ps mm) <br /> I�OIODEL 3O���V MODEL�O'I 1 SG RAATER9ALS APPROVALS <br /> I�—s�I Handle:Steel UL and ULC Listed: <br /> } Stem: Rod Brass [EX4019(N)&DC4533(N)] <br /> I~B~ � Ball:C.P. Bronze FM Approved <br /> I � ° �� ��'� Body: Bronze NYC-BSA No.720-87-SM <br /> o Valve Seat:�rgin Teflon� <br /> A ":�_� c t � Relief Valve:Bronze �� <br /> 1 ° Bypass Fittings: Brass �, <br /> 1 Bypass Tubing:Nylobraid ���� <br /> � Sight Glass:Bronze&Glass MADE IH O.S.A. <br /> �ROIVi THE �F�� 13 °�0�7 �DITION <br /> Models 3011 BV,3011SG,3011A,&3011ASG,depending on the variant chosen,provide some or all of the requirements listed below: <br /> Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. <br /> Chapter 8.16.2.4.2 Drain connections, Interior sectional or floor control valve(s)—shall be provided with a drain connection <br /> &8.16.2.4.3 having a minimum size as shown in Table 8.16.2.4.2. <br /> Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. <br /> Chapter 8.16.2.4.6 The test connection shall be permitted to be used as main drain connection. <br /> Chapter A.8.17.4.2 (Wet Pipe System)test connection is permitted to terminate into a drain capable of accepting full flow... <br /> using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow <br /> equivalent to one sprinkler...(M3011 SG and M3011ASG only) <br /> Chapter 8.17.4.2.2 The test connection valve shall be readily accessible <br /> Chapter 8.17.4.2.4 shall be permitted to be installed in any location ...downstream of the waterflow alarm. <br /> Chapter 7.1.2 -a gridded wet pipe system shall be provided with a relief valve set to operate at 175 PSI or 10 PSI in excess <br /> of the maximum system pressure,whichever is greater. <br /> Chapter 8.16.1.2.3* A relief valve of not less than�/z" in size shall be provided on the discharge side of the pressure-reducing valve <br /> set to operate at a pressure not exceeding 175 psi. <br /> Chapter A8.16.1.2.3 -consideration should be given to piping the discharge from the(pressure reliefl valve <br /> Chapter 8.17.4.3.1 (Dry Pipe System)a trip test connection not less than 1" in diameter,terminating in a smooth bore corrosion- <br /> resistant orifice,to provide a flow equivalent to one sprinkler... <br /> Chapter 8.17.4.3.2 The trip test connection...with a shutoff valve and plug not less than 1",at least one of which shall be brass. <br /> � . � . . <br /> AGF Manufacturing Inc. Job Name: <br /> 100 Quaker Lane,Malvern,PA 19355 <br /> Phone:610-240-4900 Architect: <br /> I Fax:610-240-4906 Engineer' <br /> www.testandrain.com <br /> Contractor• <br />