17-18674
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18674
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/3/2018 2:00:43 PM
Creation date
5/3/2018 2:00:35 PM
Metadata
Fields
Template:
Building Department
Company Name
WALNUT GROVE TOWNHOMES
Building Department - Doc Type
Permit
Permit #
17-18674
Building Department - Name
BUTTERFIELD MOBILE HOME SVC INC
Address
37739 PRAIRIE ROSE LP LOT 33
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
140
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
._; <br /> FORM R405-2014 , <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method � <br /> � <br /> Project Name: R0617256 Unit 8-2 to 8-5 Builder Name: Butte�eld � <br /> Street: 4408 Court St Permit Office: City of Zephyrhills <br /> City,State,Zip: Zephyrhills,FL,33542 Permit Number: ��(�7�, <br /> Owner: "Typical"-Units 8-2 thru 8-5 Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) ' <br /> I <br /> 1. New construction or existing New(From Plans) 9. Wall Types(640.0 sqft.) Insulation Area � <br /> a.Concrete Block-Ext Insul,Exterior R=5.0 453.33 ft' � <br /> 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 186.67 ft2 I <br /> 3. Number of units,if multiple family 1 c.N/A R- ft= � <br /> 4. Number of Bedrooms Z d.N/A R= ft= ! <br /> 5. Is this a worst case? No 10.Ceiling Types (1267.0 sqft.) Insulation Area � <br /> a.Under Attic(Vented) R=38.0 1267.00 ft <br /> 6. Conditioned floor area above grade(ft� 1267 b.N/A R= ftz , <br /> Conditioned floor area below grade(ft� 0 c.N/A R= ftZ <br /> 11.Ducts R �Z <br /> 7. Windows(47.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:ah 6 175 , <br /> a. U-Factor: Dbl,U=0.30 47.00 ftz <br /> SHGC: SHGC=0.25 <br /> b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: a.Central Unit 22.4 SEER:14.00 <br /> c. U-Factor: N/A ft2 , <br /> SHGC: 13.Heating systems kBtu/hr E�ciency <br /> d. U-Factor: N/A ftZ a.Electric Strip Heat 171 COP•1.00 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.957 ft. <br /> Area Weighted Average SHGC: 0.250 14.Hot water systems <br /> a.Electric Cap:40 gallons �� <br /> 8. Floor Types (1267.0 sqft.) ' Insulation Area EF:0.970 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1267.00 ft2 b. Conservation features �I ' <br /> b.N/A R= ftZ None <br /> c.N/A R= ftZ 15.Credits CF,Pstat i <br /> I <br /> Glass/Floor Area: 0.037 Total Proposed Modified Loads: 35.15 pASS <br /> Total Baseline Loads: 35.27 � <br /> � <br /> I hereby certify that the plans and specifications covered by Review of the plans and , �"����'��: <br /> this calculation are in compliance with the Florida Energy specifications covered by this � «�$. '�C�C� � <br /> ,� �. �_�„� <br /> Code. ✓ ��� calculation indicates compliance � � ,_;���,�_�+�' ; <br /> al�taa with the Florida Energy Code. � fr+� � '%� ��' �� � <br /> P R E P A R E D B Y: Before construction is completed y� � � <br /> 06-27-17 � ���a'" "" � �, <br /> DATE: this building will be inspected for � "'""��}f��a; <br /> compliance with Section 553.908 � '� � I <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. ,� �. � ! <br /> � ����� ; <br /> with the Florida Energy Code. ,� � <br /> i <br /> OWNER/AGENT: BUILDING OF ICIAL: � <br /> - - �-- - ----. - - --------- �-- <br /> -- --DATE:-------- --- -DATE: --- -- i <br /> I ' <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as � <br /> certifed factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> 6/27/2017 6:47 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 � <br /> � <br /> i <br /> I <br /> I <br />