Laserfiche WebLink
. ' i , <br /> -�- wrightsoft Manual S Compliance Report Job: R0617256 ' <br /> � Date: 06-26-17 <br /> Entire Unit By: TMN <br />, Bahr's Propane Gas 8�AC Inc , <br /> 4441 Allen Rd,Zephyrhilis,FL 33541 Phone:813-782-5013 , <br /> � • ' • • � <br /> For: Typical- End Units &1 and 8-6 <br /> 4408 Court St, Zephyrhills, FL 33542 <br /> � • • • • <br /> Design Conditions ! <br /> Outdoor design DB: 91.4°F Sensible gain: 19604 Btuh Entering coil DB: 78.4°F i <br /> Outdoor design WB: 77.2°F Latent gain: 5199 Btuh Entering coil WB: 64.2°F , <br />�� Indoor design DB: 75.0°F Total gain: 24803 Btuh <br /> Indoor RH: 50% Estimated airflow: 927 cfm � <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split AC <br /> Manufacturer: Tempstar or Eqv. Model: N4A330A(G)KC*+FXM4X30*"A* <br /> Actual airflow: 927 cfm <br /> Sensible capacity: 20850 Btuh 106% of load � <br /> Latent capacity: 6950 Btuh 134% of load <br />' Total capacity: 27800 Btuh 112% of load SHR: 75% <br /> • . • <br /> Design Conditions <br />� Outdoor design DB: 42.9°F Heat loss: 14569 Btuh Entering coil DB: 67.2°F <br /> Indoor design DB: 70.0°F <br /> i <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Elec strip � <br /> Manufacturer: Model: <br /> Actual airflow• 261 cfm <br /> Output capaeity: 8.0 kW 187% of load Temp. rise: 95 °F ', <br /> il <br /> - - - - - - � - - - - - - - - -� -- <br /> i <br /> '� <br /> I <br /> Meets are all requirements of ACCA Manual S. <br /> 2017-Jun-27 05:54:03 <br /> �. �AICIC���SiOft� Right-Suite�Univereal 2017'17.0.10 RSU07440 Page 1 <br /> /�+ +� .Plex-Face South\R0617256 Unit&1 and&6.rup Calc=MJB Building Front faces: S <br />