My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18696
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18696
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/3/2018 2:12:00 PM
Creation date
5/3/2018 2:11:58 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18696
Building Department - Name
LENNAR HOMES LLC
Address
36053 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. _r <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name. 2386B sf ADS Builder Name: Lennar Homes <br /> street: 36053 Stable Wilk Avenue Permit Office: Cl of Zephyrhills <br /> City,State,Zip. ,FL, Permit Number ���i�'fo <br /> Owner• Lennar Homes .lurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2570.5 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1285.70 ftZ <br /> b.Concrete Block-Int Insul,Exterior R=4 1 1118.00 ftz <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 166.83 ftz <br /> 4 �Number of Bedrooms 5 d.N/A R= ft� <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1272.0 sqft.) Insulation Area � <br /> a.Under Attic(Vented) R=30.0 1120.00 ft <br /> 6. Conditioned floor area above grade(ftZ) 2389 b.Knee Wall(Vented) R=30.0 152.00 ft� <br />� Conditioned floor area below grade(ft2) 0 c.N/A R= ft� <br /> 11.Ducts R ftZ <br />� 7. Windows(168.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 477.8 <br /> a. U-Factor Dbl,U=0.54 96.00 ft' <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 38.68 ft' 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 42.0 SEER:15.00 <br /> c. U-Factor� Dbl,U=0.56 33.33 ft2 <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.50 <br /> SHGC: � <br /> Area Weighted Average Overhang Depth: 1 198 ft. <br /> Area Weighted Average SHGC: �.3Q5 14 Hot water systems <br /> 8. Floor Types (2389.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1269.00 ftz b. Conservation features <br /> b.Floor Over Other Space R=0.0 1120.00 ft= None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.070 Total Proposed Modified Loads. 70.98 pASS <br /> Total Baseline Loads: 72.83 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��'���T<qr�: <br /> this calculation are in compliance with the Florida Energy specifications covered by this �.-,� � 'w.�:± O�, <br /> Code. calculation indicates compliance ��rf;f�` _ �..�`t�:� <br /> F,: lnrti�.�:s::=:��;..�. <br /> /. with the Florida Energy Code. '' , �'' �=;, .0 <br /> PREPARED BY' �aVe �����'c Before construction is completed 'w :.t .' ."'�. � <br /> DATE: 9 P t�.,�` ""�"`....- : �,c?� . <br /> this buildin will be ins ected for I,,, <br /> I�: <br /> compliance with Section 553.908 �; � � ,. <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. :�, ����. <br /> with the Florida Energy Code. ��L�{�tfi'� , <br /> OWNER/AGENT: f / DAT DING F ICIAL. <br /> DATE: <br /> - Compliance requires certification y the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 6/12/2017 2:28 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.