Laserfiche WebLink
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> � Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 23866 sf ADS Builder Name: Lennar Homes <br /> screet: 36053 Stable Willc Avenue Perr„�t or�ce: City of Zephyrhills <br /> City,State,Zip: ,FL, pertnit Number <br /> Owner• Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing, New(From Plans) 9. Wall Types(2570.5 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1285.70 ftZ <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1118.00 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 166.83 ft� <br /> 4 Number of Bedrooms 5 d.N/A R= ftZ <br /> 5. Is this a worst case? 10.Ceiling Types (1272.0 sqft.) Insulation Area <br /> Yes a.UnderAttic(Vented) R=30.0 1120.00 ftZ <br /> 6. Conditioned floor area above grade(ft') 2389 b.Knee Wall(Vented) R=30.0 152.00 ftz <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ft2 <br /> 11 Ducts R ftZ <br /> 7. Windows(168.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 477.8 <br /> a. U-Factor� Dbl,U=0.54 96.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 38.68 ft2 �2•Cooling systems kBtu/hr E�ciency <br /> SHGC: SHGC=0.28 a.Central Unit 42.0 SEER:15.00 <br /> c. U-Factor Dbl,U=0.56 33.33 ft� <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1 198 ft. <br /> Area Weighted Average SHGC: 0.305 14 Hot water systems <br /> 8. Floor Types (2389.0 sqft.) Insulation Area a.Electric Cap.40 gallons <br /> EF.0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1269.00 ft' b. Conservation features <br /> b.Floor Over Other Space R=0.0 1120.00 ft� None <br />� c.N/A R= ftZ 15.Credits Pstat <br /> Glass/Floor Area: 0.070 Total Proposed Modified Loads. 70.98 pASS <br /> Total Baseline Loads: 72.83 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��'f��T��,� <br /> this calculation are in compliance with the Florida Energy specifications covered by this ' �'4� " ��.� {7�,, <br /> Code. calculationindicatescompliance ���i�,°''� �='''.��t.,�C, <br /> �ave �/��G� with the Florida Energy Code. ti +1rrar;�`�•.::::=�'.'4�"�,� C�. <br /> PREPARED BY• p � ������� � <br /> I�UI, Before construction is com leted �.� � -� <br /> �.'�� .:�� C7. <br /> DATE: this building will be inspected for ��� :�.• : <br /> compliance with Section 553.908 * � '� •� �:� <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. �;� , +���. <br /> with the Florida Energy Code. �.t)�WE'� <br /> OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE: � DATE: � � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifes as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house.. � <br /> 6/12/2017 228 PM EnergyGaugeOO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />