Laserfiche WebLink
. . � <br /> FORM R405-2014 � <br />� FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> - Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 3711A sf ADS Builder Name: LENNAR HOMES , <br /> street: 6502 Paden Wheel Street Permic o�ir.�: City of Zephyrhills <br /> - City,State,Zip: ,FL, Permit Number ��j�q� <br /> Owner LENNAR HOMES Jurisdiction: 611600 <br /> Design Location: FL,Tampa County• Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(3424.9 sqft.) Insulation Area <br /> 2. Single family or multiple family , Single-family a.Frame-Wood,Exterior R=11.0 1738.70 ftz <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1487.10 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 199.11 ft2 <br /> 4 Number of Bedrooms 4 d.N/A R= ft' <br />-- 5. Is this a worst case? Yes 10.Ceiling Types (2134.0 sqft.) Insulation Area 2 <br /> a.Under Attic(Vented) R=30.0 2002.00 ft <br /> 6. Conditioned floor area above grade(ftZ) 3720 b.Knee Wall(Vented) R=30.0 132.00 ft' <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ft� <br /> 11 Ducts R ft� <br /> 7. Windows(368.0 sqft.) Description Area a.Sup: 1st Floor,Ret: 1st Floor,AH:ist Floor 6 343.6 <br /> a. U-Factor Dbl,U=0.54 138.00 ft' b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 400.4 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor' Dbl,U=0.56 123.36 ft' 12.Cooling systems kBtu/hr E�ciency <br /> SHGC: SHGC=0.28 a.Central Unit 252 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor Dbl,U=0.56 106.67 ft' <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A ft2 a.Electric Heat Pump 21.8 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 3.098 ft. , <br /> Area Weighted Average SHGC: 0.303 14 Hot water systems <br /> a.Electric , Cap:40 gallons <br /> 8. Floor Types (3720.0 sqft.) Insulation Area EF 0.950 <br /> a.Floor Over Other Space R=0.0 1725.00 ft' b. Conservation features <br /> b.Slab-On-Grade Edge Insulation R=0.0 1718.00 ft' None <br /> c.other(see details) R= 277.00 ft' 15.Credits _ Pstat <br /> Glass/Floor Area: 0.099 Total Proposed Modified Loads. 101.89 pASS <br /> Total Baseline Loads: 101.96 <br /> I hereby certify that the plans and specifications covered by Review of the plans and d�'C�:$T.��.� . <br /> this calculation are in compliance with the Florida Energy specifications covered by this � ir � ' __�pY,t, <br /> Code. calculation indicates compliance ���r„°o�?� '=;,..,�. �. <br /> /,,� /" with the Florida Energy Code. y"-���` "1 � • <br /> t`�'. I1F1C4'" �'+'�:,=s•��s,��tA-�� . <br /> PREPARED BY. �aVe �Wl�'I�YG Before construction is completed w �' " �' <br /> � -.�`l�i-_...... �: . <br />� DATE: this building will be inspected for try <br /> ��::�� . <br /> compliance with Section 553.908 • , � � � � <br /> I hereb certi that this buildin as desi ned, is i com liance Florida Statutes. e�� __ �. <br /> Y fY 9, 9 P ��5. <br /> with the Florida Energy Code. �'�I){�y�'�` <br /> OWNER/AGENT: BUILDING QFFICIAL. <br /> DATE: DATE: /� " <br /> - Compliance requires certificafion by t air handler unit manufacturer that the air handler enclosure qualifies as <br /> ce�tified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> 6/13/2017 9:57 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 <br />