water meter at the service connection. Alternate locations must be approved by the City. <br /> Installation: The City is responsible for installation of any and all required backflow <br /> prevention assemblies. The installation must be in accordance with the manufacturer's <br /> requirements and City specifications. <br /> Section 26-47: Testing Backflow Prevention Assemblies: <br /> Requirements: All reduced pressure zone, double check valve assembly, and pressure <br /> vacuum breaker backflow prevention assemblies will be tested annually by the City. The tests <br /> will be performed by certified backflow prevention technicians in accordance with procedures and <br /> guidelines established by the University of Southern California Foundation for Cross-Connection <br /> Control and Hydraulic Rei earch. A backflow prevention assembly will be considered <br /> noncomplaint if the device fails to meet minimum requirements set forth by this agency. <br /> Test Results:. Test results will be available to the consumer upon request. <br /> Section 26-48: Repair and Maintenance of Backflow Prevention Assemblies: <br /> Repairs: Repairs to backflow prevention assemblies will be the responsibility of the City. <br /> All repairs must be performed in accordance with manufacturer's recommendations. <br /> Maintenance: The City will be required to maintain the backflow assembly and the <br /> surrounding site in a manner by which the device is both accessible and operational. <br /> Section 26-49: Cross-Connection Control Requirements: <br /> Residential Potable Connections: Dual check valve assembly will be required on all <br /> residential potable connections, provided, however, the City may require other backflow <br /> prevention assemblies as herein defined on residential potable connections which are located in <br /> areas of high hazard, as defined in the applicable Dept. of Environmental Protection Regulations <br /> as same now exist or may be amended. <br /> Residential Irrigation Connections: All residential irrigation connections will require a <br /> backflow prevention assembly at the point of connection. Under normal conditions, a double <br /> check valve assembly or a pressure vacuum breaker will be adequate; however, if an on-site well <br /> exists, chemical injection is utilized, or a source of toxic contamination is present, a reduced <br /> pressure zone assembly will be required. <br /> Commercial and Industrial Potable Connections: All commercial and industrial potable <br /> I = <br /> connections will require a reduced pressure zone assembly installed at the service.connection. <br /> Commercial and Industrial Irrigation Connections: All commercial ands industrial <br /> irrigation connections will require a backflow prevention assembly at the point of connection. <br /> Under normal conditions, a double check valve assembly or a pressure vacuum breaker will be <br /> adequate; however, if an on-site well exists, chemical injection is utilized, or a source of toxic <br /> contamination is present, a reduced pressure zone assembly will be required. <br /> Commercial and Industrial Fire Sprinkler Connections: Any connection installed for the <br /> purpose of providing water service to a building fire sprinkler system must_be_pr9tected by a <br /> i <br /> double detector check valve assembly. <br /> Section 26-50: Retrofitting of Existing Services: <br /> Requirements: Existing water service connections not equipped with_.a backflow <br /> 3 <br /> °R3220 0926 <br />
The URL can be used to link to this page
Your browser does not support the video tag.