My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18441
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18441
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/27/2018 8:41:17 AM
Creation date
7/27/2018 8:40:28 AM
Metadata
Fields
Template:
Building Department
Company Name
VERIZON
Building Department - Doc Type
Permit
Permit #
17-18441
Building Department - Name
SHIVA 6005 GALL LLC
Address
6011 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EnCon Services, Inc. <br /> Sign Design Calculations <br /> Job Description PREPARED BY: EnCon Services, Inc. <br /> Verizon PO Box 3613 <br /> 6011 Gall Blvd Apollo Beach, FL 33572 <br /> Zephyrhills, FL P 813-655-3373 ' <br /> 16-1 Raceway ' F 813-655-9814 <br /> Design per Florida Building Code,6th Edition(2017),Section 16 Wind Load, FLEB#9394 <br /> ASCE 7-10, Load Case: D+0 6W <br /> Design Specifications Nathan P. Presnell, PE <br /> Risk Category II FLPE 77696 <br /> Kzt 1 <br /> Exposure Factor C <br /> Kd 0.85 <br /> Kz 0.98 `���1111111l1fl/�II <br /> V 150 (mph) ������ p pR ���Oj� <br /> o� N,.:.....F ��. <br /> GCp-GCpi 1.1 Zone 4, H<60 Feet `�� Q��.• .�s�t i�� <br /> Wind Pressure 52.8 (ps� ��,��;•v�c E N SF���_rj�`�� <br /> �2;' No 7769 • � <br /> . : <br /> = * • � * - <br /> . . <br /> Sign Information � ; ; � <br /> Hei ht 3.58 ft ��� S T OF • •.�(�.` <br /> W idth 16.15 ft �Q'.� ,� P�% W; <br /> Distance ade to top 1 30 (ft ���i����S�•�R 1�,•'�`���� <br /> ��oii����NAL��J <br /> Wind Shear Force 113.37 (Ib) <br /> Weight of Sign 578.17 (Ib) DATE SIGNED: <br /> Total Shear Force= 589.18 (Ib) 2/1/2018 <br /> Total Tension Force= 1830.91 (Ib) <br /> Required Provided <br /> Fastener size Nominal 3/8 3/8 <br /> Minimum number of fasteners 10 10 <br /> Shear Force per fastener Ib 58.9 280 <br /> Tension Force per fastener Ib 183.1 352 <br /> Combination Tension and 0.73 <1 O.K. <br /> Shear ratio <br /> THREADED ROD THROUGH WALL IS PREFERRED IN ALL INSTANCES. IF IT IS NOT POSSIBLE TO USE THREADED ROD,SEE CHART BELOW <br /> FOR APPROPRIATE ANCHOR SELECTION.SIZE AND NUMBER REQUIRED ARE NOTED IN THE CHART ABOVE. <br /> WALL STRUCTURE ANCHOR TYPE <br /> WOOD BLOCKING LAG BOLT(3'EMBEDMENT)THROUGH BLOCKING <br /> EIFS OVER 518"PLYWOOD LIBERTY TOGGLE BOLT OR THRU BOLT WITH SLEEVE <br /> HOLLOW CONCRETE BLOCK,BRICK SLEEVE ANCHOR(1-112"EMBEDMEN� <br /> SOLID CONCRETE WEDGE ANCHOR(2-1/2"EMBEDMEN� <br /> CMU,SOLID CONCRETE,BRICK HILTI HIT ROD WMY-20 ADHESIVE(3112'EMBEDMENT) � <br /> ALL ANCHORS SHALL BE CHOSEN AND PLACED IN ACCORDANCE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS <br /> 2/1(2018 <br /> Verizon Zephyrhills 16-1 Raceway calc I <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.